Highway Cruiser Bus | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Highway Cruiser Bus

Public Works and Government Services CanadaW8476-134022/AFederal
Find on CanadaBuysAdd to pipeline
Published
Sep 13, 2012
Respond by
Nov 22, 2012
Latest amendment
—3 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: Agreement on Internal Trade (AIT) Tendering Procedures: If 3+ bids offer Canadian goods/services other bids will not be considered Attachment: None Competitive Procurement Strategy: Lowest/Lower Bid Comprehensive Land Claim Agreement: No Nature of Requirements: Highway Cruiser - 55 Passenger Bus

W8476-134022/A Michele Mak Telephone No. - (819) 956-3947 Michele.mak@pwgsc.gc.ca ================================================================= ==

Amendment #003 to is issued to amend the bid closing date

Delete: Closing date of 2012-11-29 @ 2:00 P.M (Eastern Standard Time EST)

Insert: Closing date of 2012-11-22 @ 2:00 P.M (Eastern Standard Time EST) ================================================================= ==

Amendment #003 to is raised to answer the following Questions

Question # 1

Paragraph 3.9.4 Cold Weather Starting Aids Page 5

(b)

Clarify that a 120 volt oil pre heater is not available and cannot be provided as this is not commercially available for the Cummins ISX engine. However, with the inclusion of a 120 volt block heater and a 45,000BTU Pro Heater an oil heater will not be required.

Answer # 1

Amend paragraph 3.9.4 by deleting sub paragraph (b)

Question # 2

Paragraph 3.9.5 Transmission Page 5

(a)

proposal will be based on providing an Allison B500 transmission with a Cummins engine brake. A transmission retarder is not available with the Allison B500 transmission and a Cummins 425 HP ISX engine

Answer # 2

Amend paragraph 3.9.5 (a) by deleting last sentence in the paragraph.

Question # 3

Paragraph 3.9.9 Suspension and Axles Page 7

(d) ii

Clarify that the drive axle has two double acting shock absorbers per side

Answer # 3

Amend paragraph 3.9.9 (d) ii to read: At least one at each side of the drive axle;

Question # 4

Paragraph 3.9.9 Suspension and Axles Page 7

(g)

Clarify that the rear drive axle has a capacity of 23,000lbs

Answer # 4

Amend paragraph 3.9.9 (a) to read: A rear axle capacity of at least 10,432.8 kg (23,000 lbs)

Question # 5

Paragraph 3.9.9 Suspension and Axles Page 7

(h)

Clarify that the tag axle has a capacity of 16,500 lbs

Answer # 5

The words at least indicate that more than the specified 15,000 lbs capacity is acceptable No need for an amendment.

Question # 6

Paragraph 3.10.1 Driver's Seat Page 7

proposal will be based on providing an Isringhausen Model 6832 air ride driver's seat which is provided with fold down armrests and a three point seat belt as requested. (See attached for details)

Answer # 6

Amend paragraph 3.10.1 (a) as follows: Remove "six way" from the first sentence

Question # 7

Paragraph 3.10.1 Driver's Area Page 7

(c) iii

Clarify that both the front and left hand windshields are provided with electrically operated windshield blinds as requested, however the driver's side window is provided with a manually adjusted windshield blind.

Answer # 7

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 8

Paragraph 3.10.1 Driver's Area Page 7

(e)

Clarify that all passenger windows are tinted with the exception of the front LH and RH windshields as well as the driver's side windows in keeping with current Federal Motor Vehicle regulations.. However pull down sun shades are provided on all three of these windows.

Answer # 8

Amend paragraph 3.10.1 (e) to read: Tinted glass in all windows. A window curtain or a pull down sun shades in lieu of tinted window in the driver's left side window, the front left hand and right hand windshields as per CMVSS.

Question # 9

Paragraph 3.10.1 Driver's Area Driver's Protective Panel Page 8

(i)

proposal will be based on providing our standard driver's protective panel which is 33.75 inches in height from the floor and will include a one piece guard rail on top of the panel.

Answer # 9

Amend paragraph 3.10.1 (i) to read: OEM standard driver's protective panel.

Question # 10

Paragraph 3.10.4 Warning Devices Page 9

(c)

proposal will be based on providing a transmission temperature gauge on the dash in lieu of a warning light.

Answer # 10

Amend paragraph 3.10.4 (c) to read: A warning light or a transmission temperature gauge for high transmission temperature;

Question # 11

Paragraph 3.10.4 Warning Devices

(e)

proposal will be based on providing a visual warning for the entrance door only.

Answer # 11

Amend paragraph 3.10.4 (e) to read: A warning light to indicate unlatched entrance doors.

Question # 12

Paragraph 3.10.4 Warning Devices

(j)

proposal does not include a reverse sensing system as our experience has been that these systems are not reliable. However a back up camera is provided with color monitor as requested in paragraph 3.13.8

Answer # 12

Agreed. Amend paragraph 3.10.4 by deleting sub para (j).

Question # 13

Paragraph 3.10.5 Controls (f) Page 10

proposal will be based on providing our standard intermittent windshield wipers and washers. Wiper and washer switch is part of the driver's turn signal switch. And is a push to activate control.

Answer # 13

Amend paragraph 3.10.5 (f) to read: Intermittent windshield wipers and washers.

Question # 14

Paragraph 3.10.6 Audio/Video Systems Page 10

(a)

Clarify that the speakers are mounted in the parcel rack housings above the side passenger windows. A total of 8 speakers are installed on the roadside and 7 on the curbside of the coach. Additionally 2 speakers are mounted in the driver's modesty panel.

Answer # 14

This should be 3.10.6 (b) not (a). Amend paragraph 3.10.6 (b) to read: Additional passengers' speakers in addition to the normal radio speakers. One speaker per two passengers mounted below the parcel rack shall(E) be provided. This does not apply to the three rear seats. The radio shall be equipped with a volume control for the speakers in the passenger area with master control in the driver's area;

Question # 15

Paragraph 3.10.6 Audio/Video Systems Page 10

(d)

will provide the two microphone jacks as requested. One is located to the right of the driver at the back of the driver's console the other is located left if the driver on the side instrument panel.

Answer # 15

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 16

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(i)

Proposal will be based on providing our standard manual reset thermal circuit breakers.

Answer # 16

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 17

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(ii)

Clarify that the main 24 volt manual reset circuit breakers are located in the battery compartment.

Answer # 17

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 18

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(iii)

Clarify that the air conditioning junction box is located in the third baggage compartment.

Answer # 18

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 19

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(iv)

clarifies that the engine and transmission bypass switches are located in the junction box at the roadside of the third baggage compartment.

Answer # 19

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 20

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(vii)

clarify that the manual rest breaker for the 12 volt master circuit is located in the battery compartment.

Answer # 20

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 21

Paragraph 3.11.1 Electrical System Features Page 11 Circuit Breakers ( C )

(vii)

Clarify that some of our junction boxes are held closed by rubber straps in lieu of quarter-turn fasteners

Answer # 21

The paragraph number should be 3.11.1 (c) viii not 3.11.1 (c) vii . This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 22

Paragraph 3.11.1Electrical System Features Page 11 Wiring

(d)

Schematics are provided in C/D Format.

Paper copies of the manuals can be provided but would not be available until 30 days after shipment of the coaches.

Answer # 22

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 23

Paragraph 3.11.2 Batteries Page 11

Clarify that our proposal is based on providing the maintenance free batteries as requested. CCA is 1150. We are not aware of any maintenance free battery available on the market with 1850 CCA.

Additionally, a sliding battery tray is not available and cannot be provided.

Answer # 23

Note the word total in paragraph. That means that the requested CCA could be achieved by more than one battery. For example, the in service 2007 DND MCI buses have 2 batteries with 1,300 CCA each for a total of 2,600 CCA. The paragraph means that the total CCA of the individual batteries shall be at least 1,850 CCA.

Amend paragraph 3.11.2 to read: Heavy-duty maintenance free batteries with a total capacity of at least 1,850-CCA shall be provided. The following shall(E) also be provided:

A battery disconnect switch located in a protected area, accessible through the battery compartment door; and

A set of slave start colour coded metal pins located in an easily accessible location.

Question # 24

Paragraph 3.11.3 Lighting Page 12

(a)

advises that the headlights provided will be LED Headlights

Answer # 24

Amend paragraph 3.11.3 (a) to read: Headlights;

Question # 25

Paragraph 3.11.3 Lighting

(d)

Clarify that rear turn signal lights are red and the side turn signal lights are Amber

Answer # 25

Amend paragraph 3.11.3 (d) to read: Rear turn signal lights and mid ship left and right turning lights;

Question # 26

Paragraph 3.11.3 Lighting Page 12

(e)

Clarify that the fog lights provided will be non LED

Answer # 26

Paragraph 3.11.3 states: All interior and exterior lights shall be LED, as commercially available. The non LED fog lights are acceptable, if not commercially available.

Question # 27

Paragraph 3.11.3 Lighting Page 12

(i)

proposal is based on providing the step well light which is attached to the passenger side of the front entrance door.

Answer # 27

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 28

Paragraph 3.11.3 Lighting Page 12 (l)

i Entrance Step well

Advise that our entrance step well has one light in the ceiling over the step well area and one light on the passenger side of the front entrance door

Answer # 28

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question 29

Paragraph 3.11.3 Lighting Page 12 (l)

iii Instrument Panel

Clarify that we will provide a dimmer switch which is a rocker switch in lieu of a rheostat

Answer 29

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 30

Paragraph 3.11.3 Lighting Page 12 (l)

iv 2 and 3 Overhead Lighting

proposal will be based on providing overhead LED lighting in lieu of fluorescent lights

Answer # 30

Amend paragraph 3.11.3 (i) iv 2 to read: In the "LIGHTS" position, the LED light located overhead at the aisle-side of the parcel racks should be on;

Amend paragraph 3.11.3 (i) iv 3 to read: In the "COACH" position, the LED light above the windows will be illuminated in addition to the aisle position lights, providing the keyed ignition switch is "ON";

Question # 31

Paragraph 3.11.3 Lighting Page 12 (l)

vii Lavatory Lighting

Advise the light in the lavatory is 24 volts

Answer # 31

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 32

Paragraph 3.11.3 Lighting Page 12 (l)

viii Night Lighting

Advise the night lighting will be LED in lieu of fluorescent

Answer # 32

Amend paragraph 3.11.3 (i) viii to read: LED low output night lights.

Question # 33

Paragraph 3.12.3

(c)

Clarify that the flooring is located in a non-sealed area protected by the baggage bays and is edge sealed only.

Answer # 33

Amend paragraph 3.12.2 (c) to read: Bottom surface of wood product flooring shall(E) be coated and sealed at a minimum with epoxy paint when not exposed directly to moisture. Areas subject to water spray shall(E) be coated with waterproof substance;

Question # 34

Paragraph 3.12.4 Body Construction Page 14

(g)

Clarify that the rear enclosure panel and lavatory doors are made of ABS and covered with fabric. Fabric color selection can be chosen from the manufacturers standard offering if we are the successful bidder.

Answer # 34

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 35

Paragraph 3.12.4 Body Construction Page 14

(h)

proposal will be based on providing our standard Fiberglass Reinforced Plastic longitudinal air ducts

Answer # 35

Amend paragraph 3.12.4 (h) to read: Stainless steel or Fiberglass Reinforced Plastic longitudinal air ducts shall be provided;

Question # 36

Paragraph 3.12.4 Body Construction Page 14

(i)

Clarify that the upper portion of the entrance door and to the left of driver's area below the driver's left hand console is ABS material in lieu of fiberglass reinforced plastic

Answer # 36

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 37

Paragraph 3.12.4 Body Construction Page 14

(j)

proposal will be based on providing our standard painted abs panel covering the driver's evaporator assembly.

Answer # 37

Amend paragraph 3.12.4 (j) to read: Painted louvered aluminum or fiberglass panel covering the driver's evaporator assembly to the right of the driver's position shall(E) be provided;

Question # 38

Paragraph 3.12.8 Heating, Ventilation and Air Conditioning Systems (HVAC) Page16

(c)

proposal will be based on providing a Bitzer air conditioning compressor in lieu of Carrier.

Answer # 38

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 39

Paragraph 3.12.8 Heating, Ventilation and Air Conditioning Systems (HVAC) Page16

(c) ii

The system capacity of the a/c system for the passenger area is 122,000 BTU's.

Answer # 39

Amend paragraph 3.12.8 (c) ii to read: A capacity of at least 122,000-Btu/hour in the passenger area, and at least 35,000-Btu/hr for the driver's area;

Question # 40

Paragraph 3.12.8 Heating, Ventilation and Air Conditioning Systems (HVAC) Page16

(d) i

Clarify that the heater/air conditioner blowers serving the passenger area provides 1000cfm on low speed and 2060cfm on high speed.

Answer # 40

Amend paragraph 3.12.8 (d) i to read: The heater/air conditioner blowers serving the passenger area shall be capable of providing at least 1000-cfm on low speed, and at least 2060-cfm on high speed;

Question # 41

Paragraph 3.12.9 Interior Features

(a) Passenger Seats and Seating

i 1and2

proposal will be based on providing Amaya PG passenger seats in a 56 passenger seat layout. Please see attached seat brochure and seat layout diagram.

Top of seat back height is 43.2 inches measured from the top of the headrest in the lowered position. Additionally, seat spacing is 30 inches from the rear of one back rest to the rear of the next.

Answer # 41

The requirement is for at leas 55 passengers. Number of seats of 56 passengers is acceptable. No need for an amendment for paragraph 3.12.9 (a) i 1.

Amend paragraph 3.12.9 (a) i 2 to read: Approximately 914-mm (36-in) wide, at least 1,092-mm (43-in) high as measured from the top of the headrest in the lowered position, and spaced at least 762-mm (30-in) apart as measured from the rear of one backrest to the rear of the next;

Question # 42

Paragraph 3.12.9 Interior Features

(a)i6

Clarify that Automatic retracting footrests will be provided however, they are made of composite material and not Stainless Steel

Answer # 42

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 43

Paragraph 3.12.9 Interior Features

(b) Overhead Parcel Racks Page 17

(i)

Clarify that enclosed aircraft type parcel racks with fabric covering will be provided as requested however, individual lights are not provided behind the closed parcel rack doors.

Answer # 43

The inquiry is not clear. The paragraph states the following: "Enclosed parcel racks, aircraft type with carpeting and lights shall be provided". There is no indication that the lights are to be provided behind the closed parcel rack doors.

Question # 44

Paragraph 3.12.9 Interior Features

(b) Overhead Parcel Racks Page 17

ii

Clarify that the speakers are mounted in the parcel rack housings above the side passenger windows. A total of 8 speakers are installed on the road side and 7 on the curbside of the coach. Additionally 2 speakers are mounted in the driver's modesty panel

Answer # 44

This paragraph doesn't provide the requirement for speakers. It specifies the requirement for the integral handrail along the aisle side. However, the speakers were addressed in Question/Answer # 14.

Question # 45

Paragraph 3.12.9 Interior Features

(c) Walls and Ceiling

Clarify that the interior ceiling panels are aluminum with fabric covering sound deadening perforated acoustic headlining is not available.

Answer # 45

Amend paragraph 3.12.9 (c) to read: The walls shall be covered with fabric compatible with the seats fabric. The ceiling shall(E) be covered with fabric or vinyl clad aluminum material(s).

Question # 46

Paragraph 3.12.11 Passenger Entrance Door page 18

v

Clarify that an exterior entrance door switch is provided as requested However switch is flush mounted and not installed in a pocket

Answer # 46

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 47

Paragraph 3.12.11 Passenger Entrance Door page 18

vi

Clarify that a stainless steel latch assembly is not provided in the front entrance area but is accessible from the front dash area.

Answer # 47

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 48

Paragraph 3.12.12 Service Doors Page 18

Advise that locking doors will be provided on all requested doors except for the engine, radiator and electrical panel, and LH side service door.

Answer # 48

Amend paragraph 3.12.12 to read: Service doors shall be equipped with electronic or manual locking device. The service doors shall(E) be for the following, as applicable:

(a) Spare Tire Access;

(b) Condenser Compartment;

(c) Fuel Tank Access and Filler; and

(d) Battery Compartment.

Question # 49

Paragraph 3.12.13 Step well Page 19

(a)

Confirm that our proposal will be based on providing heated step treads in the entrance area. Additionally, the step well construction is fiberglass reinforced plastic.

Answer # 49

Amend paragraph 3.12.13 (a) to read: A heated step well shall be provided

Question # 50

Paragraph 3.12.13 Step well Page 19

(c)

Advise that the insulation provided is installed underneath the step well area.

Answer # 50

Amend paragraph 3.12.13 (c) to read: Step well shall be insulated to reduce heat and sound transfer.

Question # 51

Paragraph 3.12.13 Step well Page 19

(e)

will provide the grab handles as requested however, they are made from Molded Polyurethane

Answer # 51

Amend paragraph 3.12.13 (e) to read: Stainless steel or molded polyurethane tube grab rails with knuckle clearances, on both sides of the entrance and horizontally on top of the dash shall be provided; and

Question # 52

Paragraph 3.12.14 (c) Bumpers Page 19

Clarify that both front and rear bumpers are energy absorbing molded fiberglass reinforced plastic. As a result e coating or anodizing is not required.

Answer # 52

Amend paragraph 3.12.14 (c) to read: Bumpers shall be painted, e-coated, or anodized on all sides prior to installation. If the bumpers are energy absorbing molded fiberglass reinforced plastic, the e coating or anodizing shall not be required; and

Question # 53

Paragraph 3.13.4 Fenders and Splash Guards page 20

(a)

Clarify that our fenders are one piece fiberglass and molded directly on to the front and rear wheel housing panels.

Answer # 53

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 54

Paragraph 3.13.4 Fenders and Splash Guards page 20

(b)

Clarify that the front and TAG axle splashguards are 19 inches X 9 inches wide and the rear drive axle splash guards are 29 inches X 24 inches wide

Answer # 54

Amend paragraph 3.13.4 (b) to read: Front and rear splashguards.

Question # 55

Paragraph 3.13.6 Emergency Equipment Page 20

(b)

The reflector triangles and flares will be installed in the # 1 Baggage bay

Answer # 55

Amend paragraph 3.13.6 (b) to read: Three collapsible reflector triangles;

Question # 56

Paragraph 3.13.6 Emergency Equipment Page 20

(c)

Answer # 56

Amend paragraph 3.13.6 (c) to read: Three signal flares, in a container;

Question # 57

Paragraph 3.13.6 Emergency Equipment Page 20

(d)

Clarify that the proposed fire axe will be 12 inch in lieu of requested 15 inch.

Answer # 57

Amend paragraph 3.13.6 (d) to read: One at least 12-inch fireman's axe, securely mounted and readily accessible in the proximity of the driver;

Question # 58

Paragraph 3.13.6 Emergency Equipment Page 20

(e)

proposal will be based on providing a 5 lb fire Extinguisher

Answer # 58

Amend paragraph 3.13.6 (e) to read: A 2.27-kg (5-lb) with a minimum 5BC rating, dry chemical fire extinguisher in a recessed box under the #2 curbside passenger seat; and

Question # 59

Paragraph 3.14.1 Paint Finish Page 21

(a)

proposal will be based on providing our standard Dupont Imron Elite one stage paint finish.

Answer # 59

The requirement as detailed in paragraph should be followed.

Question # 60

Paragraph 3.14.1 Paint Finish Page 21

(b)

Clarify that our entire frame is manufactured entirely from stainless steel with the exception of the rear bogie assembly which is provided with under coating and then painted.

Answer # 60

This is a shall(E) requirement and deviations are subject to Technical Authority Approved Equivalent. No need for a paragraph amendment. Note definition in paragraphs 1.2 (b) & 1.2.1 (b).

Question # 61

Paragraph 3.14.1 Paint Finish Page 21

(d)

Please refer to our comments for paragraph 3.12.3

Answer # 61

Amend paragraph 3.14.1 by deleting sub paragraph (d)

Delivery Date: Above-mentioned

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 3 amendments. CanPursue observed 1 of them with dates.

  • Amendment 3Jun 10, 2013
  • Original noticeSep 13, 2012

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
W8476-134022/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.