Create free accountTrade Agreement: NAFTA/AIT/Canada FTAs with Peru/Colombia/Panama Tendering Procedures: All interested suppliers may submit a bid Attachment: None Competitive Procurement Strategy: Lowest/Lower Bid Comprehensive Land Claim Agreement: No Nature of Requirements: Amendment 001 is raised to change the name of the Contracting Authority. ***************************************************************** ********************************************************
IMPULSE NOISE MEASUREMENT SYSTEM
W7719-145241/A Brewster, Shannon Telephone No. - (905) 615-2028 Fax No. - (905) 615-2060 E-mail - shannon.brewster@pwgsc-tpsgc.gc.ca
Defence Research and Development Canada (DRDC) requires supply and delivery of one (1) fully-functional Impulse Noise Measurement System and all related materials listed in the Request for Proposal (RFP) Annex A Requirement to be delivered to DRDC Toronto, Ontario within eight (8) weeks from the date of award of the contract. Training of the system must be completed within two (2) weeks from date of delivery.
The bidder must demonstrate that they meet every mandatory evaluation criteria in their bid by submitting supporting documentation. Failure to provide supporting documentation by bid closing date will result in the bid being deemed non-responsive.
Few of the mandatory evaluation criteria are listed below. Please refer to the RFP (ANNEX "C") for the complete list of mandatory evaluation criteria.
1. The system must include a pressure-blast probe for measurement of an impulse noise signal, and an acoustic test fixture (ATF) for the measurement of the insertion loss (i.e., sound attenuation) of hearing protection devices. The system must be a commercial off-the-shelf product.
2. Must have a free-field pressure probe (quantity: 1): Must measure the impulse noise signal in air. The probe must conform to ANSI 12.42-2010. The microphone inside the probe must:
a. Measure impulse levels between 130 dB to 180 dB; and
b. Have a frequency response greater than or equal to 20 Hz and less than or equal to 20 kHz with 3dB.
A bid must comply with the requirements of the bid solicitation and meet all mandatory technical evaluation criteria to be declared responsive. The responsive bid with the lowest evaluated price will be recommended for award of a contract.
The Bidder must submit pricing in accordance with Annex B - Basis of Payment, in Canadian Funds. Delivery Date: Above-mentioned
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user