Shielded Chambers including install | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Shielded Chambers including install

Public Works and Government Services CanadaU4030-208961/AFederal
Find on CanadaBuysAdd to pipeline
Published
Oct 17, 2019
Respond by
Nov 26, 2019
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: CETA / WTO-AGP / CPTPP / NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: All interested suppliers may submit a bid Competitive Procurement Strategy: Lowest/Lower Bid Comprehensive Land Claim Agreement: No Nature of Requirements:

Shielded Chambers including install

U4030-208961/A Courteau, Robert Telephone No. - (343) 550-1614

General Requirement Preamble

The Certification & Engineering Bureau (CEB) at Innovation, Science and Economic Development Canada requires three (3) shielded chambers in order to carry out regulatory compliance testing, standards development activities as well as measurement studies.

Equipment Specification Requirements

A turnkey shielded chamber is a ?ready for use? standalone room that provides isolation from external sources of radio frequency (RF) noise and minimizes internal reflections of RF signals to reduce multipath interference. The shielded chambers shall be lined with RF absorbing materials and have alternating current (AC) line filters to reduce the amount of noise that may propagate on the AC power line.

The specification requirements outlines the technical requirements for the shielded chambers and the installation.

Chamber 1 - Mandatory Requirements

Chamber and related component Specifications

RF-Shielding

Specification requirement

• The minimum internal dimensions of the chamber shall be equal to or greater than 3.75 m long, 3 m high and 3 m wide.

RF-Shielded Door

Specification requirement

• The minimum door size shall be 4’ x 7’. • The door shall be a single-leaf manual door.

Waveguide Air Vents

Specification requirement

• The minimum of two 18? x 18?, or larger, waveguide air vents

Power line filters

Specification requirement

• The minimum of two dual line 30A power line filters • The power line filters shall meet the applicable CSA, or equivalent, electrical safety standards • The power line filters shall have a threaded brass ground stud

Lighting

Specification requirement

• There shall be an LED lighting kit which includes a power supply, filter and a minimum of two LED lights

Camera System

Specification requirement

• There shall be a camera system included which includes filter, network switch and video cable. • The camera shall be wall mounted.

Connector panel and penetrations

Specification requirement

• There shall be a blank connector panel measuring a minimum of 12? x 12? • There shall be a means of connecting a sprinkler system • There shall be a general purpose pipe penetration to provide access for cables with a minimum diameter of 1?

Floor

Specification requirement

• The building floor shall be covered by a dielectric underlay and vapor barrier • The interior chamber floor shall be covered with vinyl floor tile

Absorber Materials

Walls and ceiling

Specification requirement

The internal walls and ceiling shall be lined with ferrite panels and an RF absorbing material with the following characteristics: o The maximum height of the absorber shall be less than 21 cm o The reflectivity of the combined ferrite and absorber shall be less than -10 dB over the frequency range of 30 MHz to 40 GHz

Chamber 2 and 3 - Mandatory Requirements

Chamber and related component Specifications

RF-Shielding

Specification requirement

• The minimum internal dimensions of the chamber shall be 3.75 m long, 3 m high and 3 m wide.

RF-Shielded Door

Specification requirement

• The minimum door size shall be 4’ x 7’. • The door shall be a single-leaf manual door.

Waveguide Air Vents

Specification requirement

• The minimum of two 18? x 18?, or larger, waveguide air vents

Power line filters

Specification requirement

• The minimum of two dual line 30A power line filters • The power line filters shall meet the applicable CSA, or equivalent, electrical safety standards • The power line filters shall have a threaded brass ground stud

Lighting

Specification requirement

• There shall be an LED lighting kit which includes a power supply, filter and a minimum of two LED lights

Camera System

Specification requirement

• There shall be a camera system included which includes filter, network switch and video cable. • The camera shall be wall mounted.

Connector panel and penetrations

Specification requirement

• There shall be a blank connector panel measuring a minimum of 12? x 12? • There shall be a means of connecting a sprinkler system • There shall be a general purpose pipe penetration to provide access for cables with a minimum diameter of 1?

Floor

Specification requirement

• The building floor shall be covered by a dielectric underlay and vapor barrier • The interior floor shall be covered with vinyl floor tile Absorber Materials Walls and ceiling

Specification requirement

• The interior walls and ceiling shall be lined with an RF absorbing material with the following characteristics: o Reflectivity shall be less than -35 dB over the frequency range of 1 GHz to 40 GHz o The maximum height shall be less than 32 cm General Requirements Freight

• Delivery of the components of the chamber to the CEB shall be included. The CEBs location is 3701 Carling Ave, Building 94, Ottawa, Ontario K2H 8S2.

Installation

• Design and installation of the chamber (enclosure and absorbers) shall be included and shall be completed by March 31, 2020. The installation is at the CEBs location, 3701 Carling Ave, Building 94, Ottawa, Ontario.

Performance Testing

Specification requirement

• The installed chamber’s shielding performance shall be verified against the requirements of MIL-STD-285 at 1 GHz.

Delivery Date: Above-mentioned

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
U4030-208961/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account