Create free accountTrade Agreement: CETA / WTO-AGP / NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Interchangeable Parts Comprehensive Land Claim Agreement: No Vendor Name and Address: Rohde & Schwarz Canada Inc. 1 Hines Road, Suite 100 Ottawa Ontario Canada K2K3C7 Nature of Requirements:
EMI Test Receiver
Innovation, Science and Economic Developement Canada has a requirement for the procurement of an Electromagnetic Interference (EMI) Test Receiver for deliver to Ottawa, Ontario by March 22, 2019.
Frequency Range - The minimum frequency range must be from 2 Hz to 44 GHz.
Maximum RF Input Power - The maximum RF input power over the frequency range of the instrument must be greater than or equal to 0 dBm.
Amplitude Accuracy - The level accuracy over the entire frequency range of the instrument must not exceed ±3.5 dB.
Display Amplitude Resolution - The amplitude resolution over the entire frequency range of the instrument must be less than or equal to 0.1 dB.
Display Frequency Resolution - The frequency resolution over the entire frequency range of the instrument must be less than or equal to 1 Hz.
Frequency Response - The frequency response over the entire frequency range of the instrument must not exceed ±4.5 dB.
Display Sweep Points - The number of display sweep points must be greater than 100,000 in the analyzer mode and 200,000 in receiver mode.
Resolution Bandwidth (RBW) Range - The RBW range must be from 1 Hz or lower to 80 MHz or greater. All CISPR RBW (200 Hz, 9 kHz, 120 kHz, 1 MHz) as listed in CAN/CSA-CISPR 16-1-1:15.
Video Bandwidth (VBW) Range - The video bandwidth (VBW) range must be from 1 Hz or lower to 80 MHz or greater.
Displayed Average Noise Level (DANL) - Over the entire frequency range of the instrument, with no features (such as preamplifiers), the displayed average noise level (DANL) must not be greater than -100 dBm.
Third Order Intermodulation Intercept Point (TOI) - Over the entire frequency range of the instrument, with no features (such as preamplifiers), the third order intermodulation intercept point (TOI) msut be at least 10 dBm.
1dB Compression Point - Over the entire frequency range of the instrument, with no features (such as preamplifiers), the 1dB compression point must be 0 dBm or greater.
Mechanical Attenuation Range - The mechanical attenuation range must be from 0 dB to at a minimum 60 dB.
Mechanical Attenuation Steps - The mechanical attenuation step size must be 5 dB or lower.
Precision Oscillator - The instrument must include a high stability precision oscillator with an aging rate of less than ±3 x 10-8 per year.
External Mixer Connection - The instrument must include Local Oscillator (LO) / Intermediate Frequency (IF) connections for the possibility of connecting either external mixers or downconverters for future use at frequencies greater than the highest frequency listed in section 1.1.1. The LO and IF interfaces may be integrated into a single connection.
External Generator Control - The instrument must include connections that allow an external generator to be controlled by the instrument.
Realtime Spectrum Analysis - The instrument must include realtime spectrum analysis software with spectrogram. The instrument must have a realtime bandwidth of 80 MHz or greater.
Low-Noise Amplifier - The instrument must include an internal low-noise amplifier from frequency range of 150 kHz to 44 GHz.
Modulation analysis of analogue modulated carrier signals - The instrument must include an integrated application that permits the demodulation of analogue signals (AM, FM and PM), that has the same analysis capabilities as an analog modulation analyzer.
Modes of operation - The Instrument must have the following detectors: a) Positive peak; b) Voltage Average; c) Sample; d) CISPR-QUASI-PEAK; e) CISPR-Average; g) CISPR-RMS - In receiver mode, the instruments detectors must be fully compliant to CISPR 16-1-1:2015 and ANSI C63.2-2016 specifications. - In receiver mode, the unit must be able to make measurements using up to three simultaneous detectors at any marker frequency.
Trace Functions - The number of traces must be greater than 2. It must be possible to display multiple traces on the screen at the same time. The trace functions shall include a ?clear? or ?free-run? option, a maximum hold option and a trace average function.
Display Scales - The display must be capable of logarithmic and linear modes. The scale units for logarithmic display capabilities must include dBm and dBuV.
RBW Step Sizes - The RBW steps must include, but not be limited to, steps in increments of 1, 3 and 5 (e.g. 100 kHz, 300 kHz and 500 kHz).
Zero Span - The instrument must be capable of entering a ?zero span? mode.
Trigger - There must be a function for triggering displayed signals. This function must include a ?clear? or ?free-run? function, a ?video? or ?line? trigger, a radio frequency ?RF? or signal trigger and an external trigger via an external input.
Measurement Features - Measurement features must be available which include the ability to display limit lines, measure the 99% occupied bandwidth, measure the x dB bandwidth, measure the channel power, measure the Complementary Cumulative Distribution Function (CCDF) and time gate.
Standard Commands for Programmable Instrumentation (SCPI) Compatibility - The Instrument must have the ability to be remotely controllable via an external computer using SCPI commands and must have SCPI remote software control commands that can be used to create limit lines on the display of the Instrument.
Environmental Requirements - The manufacturer’s operating temperature range must be in the range of 10 degrees Celsius or lower to 35 degrees Celsius or higher. - The maximum operating humidity must be equal to or higher than 70%.
Connection Requirements - The RF test port connector must be a 2.92 mm male connector. - The impedance of the RF test port connector must be 50 ohms. - The RF test port must have a Voltage Standing Wave Ratio (VSWR) specification no greater than 3.0 over the entire frequency range of the instrument - The AC power input connection must be 120 Vac, 60 Hz - The instrument must be equipped with an Ethernet (LAN) port, a General Purpose Interface Bus (GPIB) interface port for remote automation capability and at least one USB port.
User Interface - The instrument must include a user interface embedded in the equipment. - The user interface must be a colour visual screen display with either tactile user controls embedded in the instrument or a touch screen embedded in the instrument. - There must also be an external monitor connection.
Data Storage - There must be internal Solid State Drive (SSD) data storage with a minimum storage size of 32 GB. - There must also be an external data storage option via USB. - There must be the ability to store images and data traces to at least the external USB data storage.
Weight - The Instrument must not weigh more than 50 kg.
Software License - The software provided with the instrument must include a perpetual license.
Operating System - The Instrument’s operating system must be a Microsoft Windows platform.
Remote Connectivity - The Instrument must have the ability for an external computer to remotely connect to the Instrument and download trace images and trace data.
Compatibility with automation software - The instrument must be fully compatible with the CEB’s automated test software EMC32.
Quality and Service - The instrument must be a standalone turnkey instrument, not a system comprised of several different pieces of equipment. - The instrument must include contact information for product support in the form of a website, email address and telephone number. The support must be available for at least 2 years after purchase.
Safety Requirements - The instrument must conform to the applicable CSA electrical standard and must contain the appropriate CSA marking.
Deliverables - All hardware components of the instrument must be delivered with a certificate of calibration and data demonstrating compliance to all the manufacturers’ specifications. The calibration must be valid for at least 1 year after purchase. - Training on how to use the equipment, in the form of a one-time orientation session delivered to Innovation, Science and Economic Development Canada personnel, must be provided by the Contractor at the Certification and Engineering Bureau, upon request.
APPLICABLE TRADE AGREEMENTS AND OBLIGATIONS
This requirement is subject to the Canadian Free Trade Agreement (CFTA),the North American Free Trade Agreement (NAFTA), the Billateral Free Trade Agreements and the World Trade Organization Agreement on Government Procurement (WTO-AGP).
GOVERNMENT CONTRACT REGULATIONS (GCR) EXCEPTION AND LIMITED TENDERING REASON
In accordance with the GCR exception, this requirement is being directed to the Rohde & Schwarz Canada Inc. (OEM) as the required items are guaranteed interchangeable with the current EMC32 software being used on-site at Industry Canada.
Limited tendering procedures are being invoked for reasons of Interchangeability with existing systems. Substitutions of this equipment would be un-safe in the short-term and in the long-term, would require many expensive changes.
REQUIRED DELIVERY
March 22, 2019
PROPOSED CONTRACTOR
Rohde & Schwarz Canada Inc. 1 Hines Road, Suite 100 Ottawa, ON K2K 3C7
CLOSING DATE FOR ACCEPTING STATEMENTS OF CAPABILITIES
October 24, 2018, 2:00 pm. EDT.
INQUIRIES AND SUBMISSION OF STATEMENTS OF CAPABILITIES
Joanne Ladouceur (M) Supply Specialist Public Works and Government Services Canada ?HN? Division 4th Floor, L'Esplanade Laurier, East 140 O'Connor Street Ottawa, Ontario K1A 0S5
Telephone: (613) 296-4282 Facsimile: (819) 953-4944
The Crown retains the right to negotiate with suppliers on any procurement. Documents may be submitted in either official language of Canada.
Delivery Date: Above-mentioned
You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.
An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.
Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user
No amendments observed.
No attachments listed in the open data.
No contact listed in the open data.