CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
MASS SPECTROMETER (HR-ICP-MS) | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

MASS SPECTROMETER (HR-ICP-MS)

Public Works and Government Services CanadaM7594-132186/AFederal
Find on CanadaBuysAdd to pipeline
Published
Oct 15, 2012
Respond by
Oct 29, 2012
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: WTO-AGP/NAFTA/AIT/Canada-Peru FTA/Canada-Colombia FTA Tendering Procedures: Generally only one firm has been invited to bid Attachment: None Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: NU INSTRUMENTS LTD UNIT 74 CLYWEDOG ROAD SOUTH United Kingdom LL13 9XS Nature of Requirements: MASS SPECTROMETER (HR-ICP-MS)

An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.

Definition of requirement The RCMP, Materials Profiling, Forensic Science & Identification Services, have the requirement for the supply, installation, training and manuals for one (1) double-focusing high-resolution Inductively Coupled Plasma - Mass Spectrometer system (df HR-ICP-MS).

Criteria for assessment of the Statement of Capabilities Any interested supplier must demonstrate by way of a statement of capabilities that its equipment meets the following requirements:

All of the following mandatory requirements must be met: 1. Compatibility With Other External Devices a) The instrument must be fully compatible and demonstrate full software control/integration for an ArF-excimer UP193fx laser ablation system (ESI-New Waves Research) and must have the option to be triggered by the laser for long pre-programmed sequence analysis (>150 analyses/sequence). NOTE: A communication cable between the mass spectrometer and the laser ablation system must be supplied with the new instrument to make that communication. b) The instrument must be compatible and demonstrate full software control/ integration of an Elemental Scientific Inc. (ESI) autosampler (SC-2 DX autosampler and FASTValve system).

2. Instrument Software a) The software must have the capacity to switch off the instrument automatically at the end of a pre-programmed sequence. b) It must demonstrate the capability to acquire data in Time Resolved Analysis (TRA; M+ cps vs time) for laser ablation work with exportable data file compatible to off-line data processing GLITTER? software. c) Must have an open source operating software that allows end-user operator to adapt or modify specific calculation and/or data monitoring/correction.

3. Instrument Accessories a) The instrument must come with 5 Mass Flow Controllers including 2 "dedicated" ones for other applications such as laser ablation (at least one of the "dedicated" MFC calibrated for helium; 2l/min). They all must be controllable via the instrument software. b) A recirculating water chiller must come with the instrument with recommended heat exchange capacity. If an extra chiller is required for a second function, then it must respect the recommended heat capacity as required. c) The system must come with all the regular glassware accessories (torch, spray chamber, PFA nebulizer) normally used for an installation test and one set of skimmer and sampler cones (Ni or Al). d) Software license, software CD (or other memory device), software document and technical application notes.

4. Instrument Specifications - ICP-MS instrumen § State-of-the-art electronics. § Fast scan technology for laser ablation analysis. § Low dark noise 1x109 cps/ppm for 115In at low resolution (300 Resolving Power). § A true linear dynamic range up to 10+9 cps in pulse counting mode for better isotopic ratio measurements in order to avoid continual changing of cross-over calibration between pulse-counting and analog mode. § Easy access spray chamber and sample interface. § Must be a double-focusing magnetic sector with magnet and electrostatic analyzer (ESA) for flat top peak isotopic measurement. § Electro magnet fully laminated allowing fast peak jumping with extremely low hysteresis. § Quantitative analysis including external calibration (laser and solution modes), standard additions, isotope ratios, isotope dilution and semi-quantitative methods must be part of the software. § The collector system must include an electron multiplier detector for pulse counting mode (up to 9 orders of magnitude) and a Faraday detector for large dynamic range (up to 12 orders of magnitude). § The ICP-torch is controlled via software for X, Y and Z directions. § The vacuum system must have a full automatic protection with an isolating valve located between the ICP and the magnetic sector mass spectrometer. § Resolution >10,000 for problematic isotopes is achievable and controllable by software. § A continuously variable resolution capability from 300 to greater than 10,000 that can be optimized for specific applications where sensitivity does not have to be compromised at the expense of over-resolution fixed-slit system. § To limit magnet "duty cycle" fast scan optics can allows up to 40% of mass range. § The "magnet scan" speed must be

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
M7594-132186/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account