CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
CONSTRUCTION:Chemical Room Acid storage Retrofit at Environment Canada’s National Hydrology Research Centre in Saskatoon (Saskatchewan) | Environment Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

CONSTRUCTION:Chemical Room Acid storage Retrofit at Environment Canada’s National Hydrology Research Centre in Saskatoon (Saskatchewan)

Environment CanadaKW405-13-0330RFederal
Find on CanadaBuysAdd to pipeline
Published
Sep 6, 2013
Respond by
Sep 24, 2013
Latest amendment
—2 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

This bid solicitation cancels and supersedes previous bid solicitation number KW405-13-0330 with a closing of August 20, 2013 at 2pm.

SITE VISITE INFORMATION All contractors intending to bid are invited to attend the site examination meeting. This will be the only opportunity to visit the site, examine the drawings and discuss projects details. All contractors attending the site visit will need to present photo identification at the front desk. The site visit will be held at the following date and location, as stated below:

September 12, 2013 at 10h30 am (Saskatoon time) Environment Canada, National Hydrology Research Centre #11 Innovation Boulevard, Saskatoon (SK) S7N 3H5

SECURITY REQUIEREMENT

(a) The security requirements for this project is [_X_] None [___] Reliability [___] Secret

(b) Company security clearance number:_________________

(c) Security level:____________

(d) Date received:______________

(e) Expiry date:¬__________________

SCOPE OF WORK

2.1 OBJECTIVE

1. ARCHITECTURAL - The work includes, but is not limited to, the following : a) Remove, repaint and reinstall existing blowout panels and steel mesh guards in storage rooms. b) Replace corroded door and door hardware in Acid Storage Room. Replace door locksets in remainder of storage rooms. c) Supply and install new HDPE shelving units in Acid Storage Room. d) Roof curbs and penetrations for associated mechanical and structural work.

2. STRUCTURAL - The work includes, but is not limited to, the following : a) Installation of 2 No. W310 beams under the existing roof and connecting to existing W360 beams. b) Installation of 6 no. HSS 102x4.8 stubs off the top flange of the new W310 beams and through the roof, prepared by others. c) Construction of Channel and angle platform off the top of the HSS 102x4.8 stubs including 6 mm plate support for fan exhaust stacks.

3. MECHANICAL - The work includes, but is not limited to, the following : a) Add new room ventilation, ductwork, roof exhaust fans b) Add glycol heating system for makeup air for room ventilation. c) Modifications to fire protection d) Add controls

4. ELECTRICAL - The work includes, but is not limited to, the following : a) Demolition of existing electric heating systems b) New 120V electrical service to five (5) exhaust fans c) New 120V electrical services to miscellaneous mechanical equipment (pumps and gas detection system) d) Replacement of corroded housings, fittings, gaskets, and/or screws e) Bonding exhaust fans to lightning protection system.

Construction MUST be completed by March 31, 2014.Contractor to mobilize to site within 3 weeks of signing the contract. No winter work allowance is permitted; all exterior work is to be completed by November 30, 2013.

INQUIRIES

Inquiries regarding this RFP requirement are to be submitted to the contracting officer listed below: File Number: KW405-13-0330R Contracting Officer: Marie-Christine Blais Phone Number: 514-496-1929 Fax Number: 514 -283-4439 Email: marie-christine.blais@ec.gc.ca

DOCUMENTS ATTACHED (List of Drawings)

A1: PARTIAL PLANS A2:PARTIAL PLANS S1: STRUCTURAL DESIGN S2: STRUCTURAL SECTIONS M1:MECHANICAL DEMOLITION, NEW M2:MECHANICAL NEW M3:MECHANICAL NEW M4:MECHANICAL SCHEDULES M5:MECHANICAL SPECIFCATIONS E1:ELECTRICAL NEW E2:ELECTRICAL SPECIFCATIONS ADDENDUM # 1 ADDENDUM # 4

Procurement

Category
Services
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 2 amendments. CanPursue observed 1 of them with dates.

  • Amendment 2Sep 23, 2013
  • Original noticeSep 6, 2013

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

No related records observed.

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
KW405-13-0330R
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account