CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Portable Emissions Measurement Systems | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Portable Emissions Measurement Systems

Public Works and Government Services CanadaK8A21-190144/AFederal
Find on CanadaBuysAdd to pipeline
Published
Aug 2, 2018
Respond by
Sep 25, 2018
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: CETA / WTO-AGP / NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: All interested suppliers may submit a bid Competitive Procurement Strategy: Lowest/Lower Bid Comprehensive Land Claim Agreement: No Nature of Requirements:

Portable Emissions Measurement Systems

K8A21-190144/A Courteau, Robert Telephone No. - (819) 420-5322 Fax No. - (819) 956-3814

Environment and Climate Change Canada (ECCC) has a requirement for the supply of three (3) different and separate emission measurement systems, whereby each system must individually meet all of the mandatory technical requirements as specified below. Bidders are free to bid on one (1), two (2) or all three (3) systems and may apply grouping discounts to multi-system bids. The three systems are as follows:

System 1: Portable Emission Measurement System and Parts Environment and Climate Change Canada’s (ECCC) Emissions Research and Measurement Section have the requirement under the Canadian Environmental Protection Act for the supply, commissioning, training, and manuals for one (1) Portable Emissions Measurement System (PEMS) including associated accessories to enable exhaust emission measurements of vehicles during real-world operation. This comprehensive system shall be composed of specialized analyzers to measure the pollutants listed below, a high speed exhaust flow meter, data acquisition, analysis, and reporting system, power control components, all designed to operate under the rigors of a real world test environment. As this testing is being performed to support the regulatory commitments of CEPA it is paramount that the instrumentation meets technical and reliability requirements and whose results are accepted by industry.

System 2: Exhaust Flow Measurement System for Large Displacement Engines Environment and Climate Change Canada’s (ECCC) Emissions Research and Measurement Section have the requirement under the Canadian Environmental Protection Act for the supply, commissioning, training, and manuals for one (1) stand-alone exhaust flow measurement system that would be used to accurately measure the volumetric and mass flow rate of raw exhaust from large displacement engines. The instrument must be designed to connect to exhaust of a vehicle and include data acquisition software to measure, and record the volumetric and mass exhaust gas flow rate. Instrument reliability and accuracy are imperative because the instrument will be used for: a) Emissions testing to support regulatory commitments of CEPA; b) Providing flow measurements for other exhaust speciation equipment at ERMS; c) Validating and comparing exhaust flow between PEMS systems

System 3: Real-Time Portable Soot Sensor Environment and Climate Change Canada’s (ECCC) Emissions Research and Measurement Section (ERMS) have the requirement under the Canadian Environmental Protection Act for the supply, commissioning, training, and manuals for one (1) portable emissions measurement system that would be used to measure the raw soot and particulate matter mass concentration from raw vehicle exhaust. The instrument must be designed to connect to exhaust of a vehicle and include data acquisition software to measure and record the mass concentration of particles according to the principles outlined in the US EPA Code of Federal Regulations Title 40, Chapter I, Subchapter U, Part §1065.915. Instrument reliability and accuracy are imperative because the instrument will be used for: a) Emissions testing to support regulatory commitments of CEPA; b) Validating and comparing particulate matter measurements between PEMS systems, field equipment, and test cells; c) Measuring particulate matter from vehicles to support ERMS research activities in a variety of combustion industry settings including on-road and off-road heavy-duty engines, advanced light-duty vehicles, and marine vessels

Delivery Date: Above-mentioned

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
K8A21-190144/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account