ANALYZER | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

ANALYZER

Public Works and Government Services CanadaK8A21-180712Federal
Find on CanadaBuysAdd to pipeline
Published
Nov 27, 2017
Respond by
Dec 12, 2017
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Interchangeable Parts Comprehensive Land Claim Agreement: No Vendor Name and Address: Magee Scientific Corporation 1916A M. L. King Jr. Way Berkeley California United States 94704 Nature of Requirements:

ANALYZER K8A21-180712

1. Advance Contract Award Notice (ACAN)

An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.

2. Definition of the requirement

Air Toxics Unit of AQRD in Environment and Climate Change Canada (ECCC) requires a Thermal/Optical Carbon Analyzer to facilitate our routine analysis, method development and research of PM2.5 in ambient air on this system to ECCC’s mandate.

The successful supplier will provide a Thermal/Optical Carbon Analyzer, along with the necessary accessories that meet the minimum essential requirements list below.

3. Criteria for assessment of the Statement of Capabilities

Any interested supplier must demonstrate by way of a statement of capabilities that its product/equipment/system (as appropriate) meets the following requirements:

1.Instrument

a) The equipment must have the following components: an analyzer with an automated boat loader to position a sample in an optical path in the volatilization furnace; an oxidizing conversion oven; a modulated diode laser system capable of producing light at seven wavelengths ranging from ~400 to ~1000 nm (including a wavelength close to 633 nm); a non-dispersive infrared (NDIR) CO2 detector; and an instrument controller to execute the analysis commands.

b) Analyzer must be operated by an instrument controller to perform OC/EC analysis.

c) Analyzer must have an automated sample boat loading system for introduction of a single sample into the optical path in the combustion furnace.

d) Analyzer must have an oxidizing oven to convert carbon into CO2, which shall be detected by a non-dispersive infrared (NDIR) detector. The detector signal range shall accommodate a wide range of carbon concentrations from 0.2 µg C/cm2 to 500 µg C/cm2.

e) Pyrolysis must be continuously monitored by both reflectance and transmittance of modulated diode laser(s) (at wavelengths of approximately 405, 445, 532, 635, 780, 808, and 980 nm) and results shall be given for both modes of pyrolysis correction.

f) Analyzer must have an injection port to enable calibration with liquid standards such as KHP and sucrose solutions,and gaseous standards such as methane and CO2.

g) All high-temperature zones, from the sample furnace to the conversion oven, must be heated with active temperature controllers.

h) Analyzer must operate from AC power of 110-120 VAC, 60 Hz.

2. Data Acquisition and Reporting System

a. The Instrument Control System must have the following hardware features

• Computer with 250 GB or greater hard disk, monitoring display, keyboard. • Windows 10 or better operating system. • USB and Ethernet ports for data transfer and archiving. • Adequate performance to allow effective simultaneous operation of the analyzer with the provided instrument software, together with supplementary programs (such as Microsoft (MS) Excel, Word, and Access).

b. The Instrument Control System must have the following software features

• Fully automated control of sample analysis. This includes acquiring data, quantitation, report generation, and the option to export data. • Real-time integration monitoring in order for an instrument operator to track analysis progress. • Automatic peak integration updates and/or batch reprocessing of changes to integration for a data set. • Raw data may be stored as database tables and ASCII files for export. • Thermograms may be exported as images into MS Word for publication.

3. Performance Specifications

a) Analysis protocols, such as IMPROVE_A, NIOSH 5040, and other variations (e.g.USEPA-STN or EUSAAR), must be able to be executed after a selection is made from a list of methods/protocols from the analysis command menu.

b) Analysis protocols may also be user programmable, including setting of temperature plateaus and hold times.

c) Sample oven must be programmable from ambient to 900°C; temperature accuracy must be within 1% or 5°C, whichever is greater.

d) The baseline signal must be within an NDIR response of 2 ppm (CO2), while the laser signal must have a standard variation of less than 2.5%.

e) A system blank analysis must show TC content below 0.3 µg C/cm2.

f) Minimum Detection Limit: After initial conditioning of the analyzer, the MDL, calculated with 3 standard deviations of replicate analyses of 20 quartz fiber filter blanks, must be

· 6.0 µg C/filter for organic carbon · 2.0 µg C/filter for elemental carbon

g) Repeatability: The relative difference between duplicate analyses for Total Carbon (TC) must be

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

  • MAGEE SCIENTIFIC CORPORATION (K8A21-180712/001/PV~000)Magee Scientific Corporation$109.5K

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
K8A21-180712
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account