Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.
Create free accountCreate a free account to see past contracts like this one: who won and at what price.
Create free accountTrade Agreement: CETA / WTO-AGP / NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: THERMO FISHER SCIENTIFIC (MISSISSAUGA) INC. 2845 Argentia Rd Unit 4 Mississauga Ontario Canada L5N8G6 Nature of Requirements:
Mass Spectrometer
H4133-182971 Martins, Christina Telephone No. - (613) 355-1973
1. Advance Contract Award Notice (ACAN)
An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.
2. Definition of the requirement
The Tobacco Control Directorate’s Science Division of Health Canada has a requirement for the supply, installation, training and manuals for a hybrid Liquid Chromatography (LC) Mass Spectrometer (MS) Instrument. The Science Division requires LC-MS instrument to establish analytical capabilities for the testing of vaping and other novel tobacco products.
3. Criteria for assessment of the Statement of Capabilities (Minimum Essential Requirements)
Any interested supplier must demonstrate by way of a statement of capabilities that its product/equipment/system (as appropriate) meets the following requirements:
A. LIQUID CHROMATOGRAPH (LC)
- LC must be capable of ultra high performance liquid chromatography and capable of generating pressure up to 15000 psi for fast chromatography analysis; - LC must be capable of performing high-throughput sample analysis; - LC must be equipped with a binary pump capable of high pressure gradient mixing; - LC column compartment must be capable of heating up to 120°C; - LC sample compartment must be capable of sample refrigeration cooling at 4°C; - Autosampler must be able to accommodate trays for standard 2 mL autosampler vials; and - LC system capable of high precision at low volume (1µL) injection.
B. MASS SPECTROMETER (MS)
- Minimum instrument’s mass range: 5-3000 m/z - MS must be capable of mass resolution of 70,000 at m/z 200 scan rate - MS must have mass accuracy
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user
No amendments observed.
No attachments listed in the open data.
No contact listed in the open data.