Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.
Create free accountCreate a free account to see past contracts like this one: who won and at what price.
Create free accountTrade Agreement: NAFTA / CFTA / FTAs with Peru / Colombia / Panama / Korea Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: BCA Scientific Inc 178 Rushton Rd Toronto Ontario Canada M6G3J3 Nature of Requirements:
Class II Type B2 biological safety cabinet with a negative pressure total exhaust isolator
H4004-173788/A Choquette, Herb Telephone No. - (613) 536-4874 Fax No. - (613) 545-8067 Email - Herb.Choquette@pwgsc-tpsgc.gc.ca
A. Advance Contract Award Notice (ACAN) An ACAN is a public notice indicating to the supplier community that a department or agency intends to award a contract for goods, services or construction to a pre-identified supplier, thereby allowing other suppliers to signal their interest in bidding, by submitting a statement of capabilities. If no supplier submits a statement of capabilities that meets the requirements set out in the ACAN, on or before the closing date stated in the ACAN, the contracting officer may then proceed with the award to the pre-identified supplier.
B. Definition of the requirement The Ontario Health Products Laboratory requires the supply and delivery of a custom combination Class II Type B2 biological safety cabinet tunnel to a negative pressure total exhaust isolator. This equipment will be used by the Ontario Health Products Laboratory for the handling of samples that contain hazardous substances.
C. For assessment of the Statement of Capabilities (Minimum Essential Requirements) the following must be met:
1.1. Specifications and Standards The equipment must be in accordance with the following specifications. This will be verified and documented by Canada. 1.1.1. General • The Class II Type B2 biological safety cabinet (BSC) and the negative pressure total exhaust isolator are to be joined as a combination unit with all materials entering the cabinet through the biological safety cabinet.
1.1.2. Class II Type B2 Biological Safety Cabinet • Must be designed to the NSF/ANSI 49 - 2016 standard for Class II Type B2 biosafety cabinetry. • Must be listed by Underwriters Laboratories or another equivalent certification body to meet Canadian requirements for electrical and mechanical integrity. • BSC must have true laminar airflow inside the work zone, with a single pass flow through design where work zone air is drawn through the cabinet’s internal exhaust HEPA filter to building exhaust. • All contaminated ducts and plenums must be maintained under negative pressure or enclosed within a negative pressure zone. • Supply HEPA filter must cover full width and depth of work area, and must be covered with a protective metal diffuser. • Must be constructed from stainless steel of minimum thickness 16 gauge in an all welded, monolithic, sealed structure to eliminate cabinet and gasket leaks • Control panel must have a touch screen electronic display allowing access to all parameters • Control panel must display date and time and alarm set points for error conditions • Control panel must display inflow and downflow values in real time • Noise level must be no more than 63 dbA at 12 inches in front of viewing window. • Must include a fixed height base stand with leg levellers that supports the cabinet at a working height of 100.3 cm (39.5?) • Average air velocity from supply filter must be between 55 and 65 FPM • Average inflow velocity at work access must be in the range of 100 - 110 FPM when front window is open to a height of 20.3 cm (8?) • Must operate on an 115V, 60Hz electrical supply drawing a maximum of 15A. • Must include at least one duplex GFI electrical receptacle on the outside front faring • Must inlcude at least one service valves (e.g. for house air) inside the work area • Must have ?bag in bag out? capability for exhaust HEPA filter replacement • Work zone must have mininum depth 55.8 cm (22?), minimum width 177.8 cm (70?), and minimum height 63.5 cm (25?) • Front window must slide vertically between fully closed position (maximum 3.8 cm [1.5?] opening) and fully open position (minimum 45.7 cm [18?] opening) • Exhaust connection must include a manually operated gas-tight damper to isolate cabinet from building ventilation when necessary • Must be easily transportable through a stanard 91.4 cm (36?) wide door without disassembly
2.2.3. Total Exhaust Negative Pressure Isolator
• Must have one chamber only with three glove ports (materials will introduced to the chamber through the tunnel from the Class II Type B2 BSC) • Must maintain a negative pressure within the work area relative to the surrounding room at all times • Must meet ISO 14644-1 Class 5 requirements for air cleanliness within the workzone • Must maintain laminar flow air supply at 16-19 air changes per minute • Must inlcude at least one service valve (e.g. for house air) inside the work area • Work zone must have mininum depth 66.0 cm (26?), minimum width 121.9 cm (48?), and minimum height 68.6 cm (27?) • Must operate on an 115V, 60Hz electrical supply drawing a maximum of 15A • Electrical cord must be a 3-wire cord at least 2.5m in length with a hospital grade plug • Must include a fixed height base stand with leg levellers that support the cabinet at a working height of 100.3 cm (39.5?) • Must include at least one hospital grade duplex electrical receptacle inside the work area (?interior receptacle?) • Interior receptacle must supply at least 3A • Interior receptacle must be equipped with drip-proof covers • Must have ?bag in bag out? capability for exhaust HEPA filter replacement • Must have one sharps container and one waste container built in below the work surface allowing for materials to be disposed from within the work area • All controls and montitors must be located in a central control panel in a position which can be viewed by someone while they are operating the equipment • Control panel must include a digital exhaust monitor system with high/low alarm setpoints • Control panel must include controls for adjusting supply airflow • Exhaust connection must include a gas-tight damper to isolate isolator from building ventilation when necessary • Must be constructed of stainless steel with all-welded pressure tight design • Cabinet workzone must be constructed from stainless steel of minimum thickness 16 gauge • Front window must be tempered glass • Front window must be hinged for access to the interior during servicing, with locking mechanism to seal the window during operation • Front window must be slanted 10-15° from vertical for optimal work with glove ports • Supply HEPA filter must cover full width and depth of work area, and must be covered with a protective metal diffuser. • All filter positive pressure plenums must be surrounded by a vacuum relative to the room • Must have separate fuse-protected circuits for the blower/lights and for the internal electrical receptacle • Must be listed by Underwriters Laboratories or another equivalent certification body to meet Canadian requirements for electrical and mechanical integrity • Must be easily transportable through a stanard 36-inch (914mm) wide door without disassembly • Lighting for the isolator work zone must be mounted externally to allow easy service to the bulbs during isolator operation • Lighting must provide at least 400 lux of illuminance at the work surface • If work zone lighting is fluorescent, the ballast must be electronic and must include thermal protection with automatic reset • Must include a differential pressure gauge displaying the negative pressure of the work zone in real time • Must include a hinged, sealed door providing access to the tunnel that connects the isolator to the BSC (see section 2.2.4)
2.2.4. Tunnel • The Class II Type B2 BSC must be connected to the Total Exhaust Negative Pressure Isolator by a tunnel to allow for transfer of materials from one to the other without risk of exposure to the operator • Tunnel must be constructed of stainless steel of minumum thickness 16 gauge • The interior dimensions of the tunnel must be at least 40.6 cm (16?) wide and 45.7 cm (18?) high • The tunnel must be designed for safe and comfortable transfer of materials by the user, taking into consideration: o the length of the tunnel o the position of the openings within the Class II Type B2 BSC and the Total Exhaust Negative Pressure Isolator o the limited range of motion available to someone handling materials within the Total Exhaust Negative Pressure Isolator through gloves
D. Applicability of the trade agreement(s) to the procurement This procurement is subject to the following trade agreement(s) o Canada Free Trade Agreement (CFTA) o North American Free Trade Agreement (NAFTA) o World Trade Agreement (WTO)
E. Justification for the Pre-Identified Supplier
1.0 Government Contracts Regulations Exception(s) The following exception(s) to the Government Contracts Regulations is (are) invoked for this procurement under subsection subsection 6(d) - "only one person is capable of performing the work").
2.0 Exclusions and/or Limited Tendering Reasons The following exclusion(s) and/or limited tendering reasons are invoked under the
a. CFTA Article: 513 b. the goods or services can be supplied only by a particular supplier and no reasonable alternative or substitute goods or services exist for any of the following reasons: (iii) due to an absence of competition for technical reasons;
b. North American Free Trade Agreement (NAFTA) Article 1016.2.b - where, for works of art, or for reasons connected with the protection of patents, copyrights or other exclusive rights, or proprietary information or where there is an absence of competition for technical reasons, the goods or services can be supplied only by a particular supplier and no reasonable alternative or substitute exists;
c. World Trade Organization - Agreement on Government Procurement (WTO-AGP) Article XV1.(b) when, for works of art or for reasons connected with protection of exclusive rights, such as patents or copyrights, or in the absence of competition for technical reasons, the products or services can be supplied only by a particular supplier and no reasonable alternative or substitute exists.
F. Delivery date: The equipment must be delivered by 29 March 2019.
G. The estimated value of the contract is $30,000 to $70,000 (GST/HST extra).
H. Name and address of the pre-identified supplier: BCA Scientific Inc. 178 Rushton Rd. Toronto, Ontario
I. Suppliers' right to submit a statement of capabilities: Suppliers who consider themselves fully qualified and available to provide the goods, described in the ACAN may submit a statement of capabilities in writing to the contact person identified in this notice on or before the closing date of this notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
J. Closing date for a submission of a statement of capabilities: The closing date and time for accepting statements of capabilities is September 25, 2018 at 2:00 p.m. EST).
K. Inquiries and submission of statements of capabilities Inquiries and statements of capabilities are to be directed to:
Herb Choquette Supply Team Leader Public Works and Government Services 86 Clarence St., 2nd Floor Kingston, Ontario K7L 1X3 Telephone: 613-536-4874 Facsimile: 613-545-8067 E-mail: Herb.Choquette@pwgsc.gc.ca
Delivery Date: Above-mentioned
You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.
An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.
Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user
No amendments observed.
No attachments listed in the open data.
No contact listed in the open data.