CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Chromatographs with flame ionization detector | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Chromatographs with flame ionization detector

Public Works and Government Services CanadaH3701-123202/AFederal
Find on CanadaBuysAdd to pipeline
Published
Dec 6, 2012
Respond by
Jan 8, 2013
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: WTO-AGP/NAFTA/AIT/Canada-Peru FTA/Canada-Colombia FTA Tendering Procedures: Generally only one firm has been invited to bid Attachment: None Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: AGILENT TECHNOLOGIES CANADA INC 2250 boul. Alfred-Nobel St-Laurent Quebec Canada H4S2C9 Nature of Requirements: ADVANCE CONTRACT AWARD NOTICE - H3701-123202/A

Guernon (mta550), Émile N° de téléphone - (514) 496-3585 Nº fax - (514) 496-3822

GSIN: N6640

Gas chromatographs with flame ionization detector / Qty (6)

The Drug Analysis Service (DAS) from Health Canada, Regions and Programs Bureau, requires the purchase of six (6) gas chromatographs with flame ionization detector. Each instrument must be equipped with an autosampler which can accommodate 150 samples with two (2) injectors, two (2) injection ports "split/splitless" type, two (2) flame ionization detectors (FID), a barcode reader (10 characters) a data processing system (computer) and a printer. In addition, the manufacturer must also provide the software needed for the proper functioning of all modules of the instrument as well as raw data recording.

Sole source justification

1. The operating software of the new instruments must be compatible with the software currently used. This is necessary for the treatment of previously acquired raw data. Over the past years, databases were built with more than 1,100 drug references. Consistency in the format of our data and a high degree of confidence in the continuity of our operations will then be assured. The use of the ChemStation platform, provided by Agilent, ensures us a seamless transition for user.

Another benefit is that no training will be required for the use of the new instruments, representing a significant saving in training time and analysis.

2. The oven must allow for up to 20 programs of temperature ramps, as well as 21 plateaus. Negative ramps must also be possible. This allows greater flexibility in the development of new method to meet the most complex separation needs.

3. The chromatographic performance regarding retention time must be 107 (± 10%). The DAS quantify a number of controlled substances and this linearity allows us a greater range of quantification.

7. The oven cooling time in typical conditions of use (450°C to 50°C; without accessories such as the 'fast GC') must be 4 minutes or less. This represents a non-negligible time economy, increasing our execution speed per analysis.

8. The system must allow pressure electronic control of ± 0.001 psi (for a pressure between 0 and 99,999 psi). Greater retention time reproducibility is then obtained.

9. Following the ISO 17025 accreditation of all the DAS laboratories, several procedures were set up to meet the requirements of the International Organization for Standardization. The creation of procedures have required a significant investment in terms of human resources (writing, revision, training, maintenance, etc.) and monetary. A change of the current platform (Agilent) would require a complete redesign of several procedures (for example, the procedures surrounding the use, maintenance and the qualification of the GC - FID).

Requirement

More specifically

1. System capabilities Electronic pressure control (EPC) with a precision to ±0.001 psi; Retention time repeatability 107 Triadecane sensitivity

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
H3701-123202/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account