Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.
Create free accountCreate a free account to see past contracts like this one: who won and at what price.
Create free accountSolicitation #: FP802-140036 Closing Date: July 22, 2014 Time: 11:00am
This requirement is for the department of Fisheries and Oceans Canada.
Title: SERVICING SECURITY SYSTEMS INSTALLED AT FISHERIES AND OCEANS CANADA BUILDINGS IN OTTAWA
Introduction: Fisheries and Oceans Canada (DFO) has several security systems presently in place at 200 Kent St., 222 Queen St. and 200 Elgin St. Throughout these buildings, DFO has installed card access readers including related door hardware to protect various operational and security zones. These security systems include but are not limited to; card access system, video surveillance system, intrusion alarms.
The NCR Security, Safety and Emergency Services (SSES) has a requirement for specific maintenance services on existing Access Control Systems located at 200 Kent St., 200 Elgin St., and 222 Queen St. (Ottawa). This requirement for services will be on an as and when requested basis for inspection and maintenance services, off site monitoring and replacement or repair services for the software and hardware of the departments Electronic Card Access System, Closed Circuit Camera System, Motion Detection Alarm System and consisting of peripheral devices listed in Annex A. The hardware is supported by Keyscan Software. The DFO is anticipating an update or replacement of the system within the next five year which may impact this contract.
Objectives of the Requirement: The main objective is to obtain a multiyear maintenance service agreement for DFO’s integrated security systems in the NCR from a service provider who can respond to service request in a timely manner at the lowest cost in the interest of the department and Canadian taxpayers. Inspection and Maintenance
1)Within one week after commencement of contract, submit in writing a detailed schedule for the preventative maintenance of the system for the duration of the contract based on the department's preventative maintenance requirements described in Annex B.
2) Verify that all equipment and software are operational and maintained as per manufacturer's specifications and department's requirement by: i) Cleaning, inspecting and verifying the operation of all access control system, to include the Uninterrupted Power Supply (UPS), repairing or changing batteries when warranted; ii) Maintain the computer system and supporting software in operational order iii) Advising the Project Manager whenever the Keyscan operation system including peripheral devices requires upgrades and upon the Project Manager's approval, providing and installing required upgrades. iv) Any upgrades of the software system will require the contractor to provide training to DFO operational personnel on the changes.
3) Maintain and update the Security System Information Register with any changes, additions, deletions, inspections to the access control system on an on-going basis, to include the Electronic Card Access System, Closed Circuit Camera System and Monitoring Control System and peripheral devices;
4) Provide 24/7 dispatching services for minor repairs within 4 hours of the reported problem
5) Provide 24/7 dispatching services by qualified technician for any failure of access control system within 3 hours of the report problem
6) Provide 24/7 dispatching services by qualified technician for any major failure of access control system within 2 hours of the report problem
7) Provide written reports detailing the work done after every reported service problem
8) Maintain and monitor the service ability of the closed-circuit television (CCTV) systems at all three locations, 200 Kent St., 222 Queen St. and 200 Elgin St.
9) Maintain a suitable store of replacement parts for the equipment list in Annex A. Off-Site Monitoring Services The Contractor shall provide off-site monitoring services on existing and new motion detected alarms at all three locations, 200 Elgin, 222 Queen and 200 Kent Street and provide status reports upon request. Special Operations - "As and when requested work"
The Contractor must: 1) Provide and replace all necessary parts and labour required to maintain the proper functionality of the access control system, All parts and components must be new; no reconditioned/rebuilt parts will be accepted.
2) Install strikes to current installation and to fit in existing or newly installed door cut-outs
3) Install purchased equipment as requested,
4) Prior to installing new equipment, provide quotes for parts and labour to the Project Manager for approval, the contractor will be responsible for all warranty repairs and replacement for equipment purchased through them,
5) Contractor is to provide all reports to the Project Manager in the format prescribed by the Project Manager
Enquiries regarding this RFP requirement are to be submitted in writing to the following: Jianna-Lee Zomer Contracting Officer, Department of Fisheries and Oceans Station 9W071, 200 Kent Street Ottawa, Ontario, K1A 0E6 Tel: (613) 993-1550 Fax: (613) 991-1297 Email: jianna-lee.zomer@dfo-mpo.gc.ca
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user
The source reports 6 amendments. CanPursue observed 1 of them with dates.
No attachments listed in the open data.
No contact listed in the open data.