CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
REPLACEMENT CENTRIFUGAL PUMP | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

REPLACEMENT CENTRIFUGAL PUMP

Public Works and Government Services CanadaF2599-165006/AFederal
Find on CanadaBuysAdd to pipeline
Published
Apr 7, 2016
Respond by
Apr 22, 2016
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: NAFTA/AIT/Canada FTAs with Peru/Colombia/Panama Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Interchangeable Parts Comprehensive Land Claim Agreement: No Vendor Name and Address: Leistritz Corporation 165 Chestnut Allendale New Jersey United States 07401 Nature of Requirements:

REPLACEMENT CENTRIFUGAL PUMP / ELECTRIC MOTOR UNIT FOR CANADIAN COAST GUARD (CCG) SHIPS

1. Definition of the Requirement

This requirement is for the Department of Fisheries and Oceans - Canadian Coast Guard (CCG) for three replacement Original Equipment Manufacturer (OEM) identical centrifugal pumps - electric motor units required that conform to original form, fit, quality, function, pressure and physical dimensions. The Coast Guard has a requirement to replace three IRONPUMP centrifugal pumps (OEM) on the CCGS Samuel Risley: a. Main Engine Cooling Raw Water Pump #1 IRONPUMP QVP 6/300 Flange data QVP. 6/300.44794/3.TP.8BAR.84.09.11. b. Main Engine Cooling Raw Water Pump #2 IRONPUMP QVP 6/300 Flange data QVP.6/300.44794/2.TP.8BAR.84.09.11. c. General Service/Fire Pump IRONPUMP QVP 2-4/300 Flange data QVP.2.4/600.44600/3.A?B.84.0614 TP.10BAR.CPN.ARS.591

In order to avoid modification to existing piping; existing flange to flange placement and physical dimensions of the pump - electric motors unit must be identical. Any modification to an Equivalent pump(s) in order to meet the flange to flange dimensions must be made at Bidder’s facilities. Physical dimensions of the pump - motor system must be identical to the original OEM pumps due to limitations of physical space.

The tight space restrictions for the pump / electric motor unit was created during the initial build of the ship and their placement at the working deck level the engine room.

Delivery date is: 30 June 2016

Mandatory Technical Criteria (MC) Replacement Pumps

MC 1: The Bidder will supply all OEM identical pump - electric motor units needed to replace the existing three centrifugal pumps - electric motor units in their entirety, including flange to flange dimensions. The replacement pumps must fit the existing piping without modification.

MC 2: The replacement pump - electric motor unit must fit the original Pump Seating Dimensions. Raw water pump #1 has a polygon seating: with a straight line base of 23.75 inches a left side of 21.5 inches at a 90 degree angle to the base, a right side of 13.75’’ at a 90 degree angle to the base, a top 11’’ line at a 90 degree angle to the 21.5’’ inch left side to the right, and a line of 14.75’’ joining the end of the 11 inch line top line to the 13.75 inches right line. Raw water pump #2 has a rectangle seating of 12.5 inches x 23 inches. G/ S Pump has a rectangle seating of 19.5 inches x 17.75 inches.

MC 3: Pump system #1: Quantity 2: IRONPUMP QVP 6/300 REPLACEMENT PUMP identical to 44.794/2+3 centrifugal pump with bare end shaft with motor ILE15-180M B5 with heater, ABS certificate, manual, test sheet and seaworthy crate. Pump sets require 600 volt 3 phase 60 Hz motors in the Delta configuration. The flange to flange distance for the Main Engine cooling pumps DN 150 flanges is 580mm. The vertical center of the flange is 250mm above the pump base. Physical dimensions of the pump - electric motor system must be identical to the original OEM pumps due to limitations of physical space. One Main Engine Cooling Raw Water Pump #1 and one Main Engine Cooling Raw Water Pump #2.

MC 4: Pump system #2: Quantity 1: IRONPUMP QVP 2-4/300 REPLACEMENT PUMP identical to 44.600 centrifugal pump with bare end shaft with motor ILE15-180M B5 with heater, ABS certificate, manual, test sheet and seaworthy crate. Pump sets require 600 volt 3 phase 60 Hz motors in the Delta configuration. The Flange to flange distance of the General Service pump DN100 flanges is 500mm. The vertical center of the suction flange is 335mm and discharge flange 215mm above the pump base. Physical dimensions of the pump - electric motor system must be identical to the original OEM pumps - electric motor due to limitations of physical space. One General Service / Fire Pump.

2. Justification

This requirement is sole sourced to Leistritz Advanced Technologies Corp., 165 Chestnut Street, Allendale, New Jersey, 07401 as they are the only known supplier capableto supply a replacement centrifugal pump with electric motor assembly that will fit the pump seating dimensions and the identical flange to flange measurements of the original equipment. The replacement pumps and electric motor assemblies must fit the existing piping and seating dimensions without modification as indicated in the requirement.

3. Applicability of the trade agreements to the procurement.

The Agreement on Internal Trade (AIT) The North American Free Trade Agreement (NAFTA)

4.Government Contracts Regulations Exception.

The following exceptions to the Government Contracts Regulations is invoked for this procurement Under subsection 6 (d) - only one person is capable of performing the work;

5. Limited Tendering Reasons

The following limited tendering reasons are invoked under the

Agreement on Internal Trade (AIT) section 506, 12 (b) - only one person is capable of performing the work. North American Free Trade Agreement (NAFTA) Article 1016, 2 (b).

6. Closingdate for a submission of a statement of capabilities is .

7. Inquiries and submission of statement of capabilities are to be directed to

Daniel Tamaro Senior Procurement Officer Portage II - 6C2 - 35 11 Laurier St. Gatineau, Quebec, K1A 0S5 Telephone: (819) 420-2892 Daniel.tamaro@tpsgc-pwgsc.gc.ca

Delivery Date: Above-mentioned

You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.

An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.

Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.

The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
F2599-165006/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account