CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
EC SEWAGE CONSTRUCTION RETENDER | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

EC SEWAGE CONSTRUCTION RETENDER

Public Works and Government Services CanadaEP076-162723/BFederal
Find on CanadaBuysAdd to pipeline
Published
Jul 28, 2016
Respond by
Aug 31, 2016
Latest amendment
—5 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: Agreement on Internal Trade (AIT) Tendering Procedures: All interested suppliers may submit a bid Competitive Procurement Strategy: Comprehensive Land Claim Agreement: No Nature of Requirements:

EC SEWAGE CONSTRUCTION RETENDER

EP076-162723/A Hoffman, Amanda Telephone No. - 873-469-4930

AMENDMENT 3 IS TO CHANGE THE CLOSING DATE FROM August 23, 2016 2pm to AUGUST 31, 2016 2PM

All other Terms and Conditions remain the same.

Only thefollowing Bidders which have been pre-qualified at Phase One of this procurement process are eligible to bid:

1. Marathon Drilling Co. Ltd. 2. Louis W. Bray Construction Limited 3. Pronex Excavation Inc.

PROJECT DESCRIPTION : Environment Canada(EC) and Climate Change Canada's are responsible for the preservation and enhancement of the quality of the natural environment, including water, air, soil, flora and fauna. This includes the conservation of Canada’s renewable resources, protection andenforcement of its water resources, and coordination of environment policies and programs for the Federal Government. Environment Canada owns and operates a complex of eight buildings located on 335 River Road used for vehicular testing, laboratories, andofficespace.

The existing Sewage Lift Station pumps sanitary sewage generated from the 335 River Road ECC facility and the NRC lab buildinglocated on the South East corner of Limebank Road and Balmoral Road into the existing privately owned forcemainalong the south side of River road discharging to the to the City of Ottawa sanitary sewer located at the intersection of River Road and Limebank Road.

The existing wet well and pump has an unsuitable configuration that complicates routine operation andmaintenance. It does not currently comply with Ministry of Environment (MOE) guidelines and a new design has been completed for its replacement. The new replacement Sewage Lift Station has been designed based on the available information provided by EC along with the following parameters: • Estimated average inflow of 0.15L/s; • Estimated average pump rate of 7.3L/s; • Pump cycle time ofapproximately 10 minutes; • Service population of 300 people and; • 1.2km of 150mm diameter force main fromthe site to a City of Ottawa gravity sewer.

The existing wet well is approximately 2.9m wide by 2.9m long by 3m deep. There are several issues with the current configuration of the wet well amongst which accessibility is poor and maintenance is difficult. The location of the current wet well is inconvenient. EC has pre-purchased the new replacement pumping station consisting of a pre-manufactured Fiberglass Reinforced Plastic (FRP) chamber, complete with pumps and control panel. These components have been delivered and are currently in storage at 335 River Road. In addition, EC has also pre-purchased a new precast concrete maintenance hole, also delivered to the 335 River Road site and in storage, which will be required to accommodate the new sewage lift station location. A contract through PWGSC on behalf of EC is required to replace the existing sewage lift station with a new sewagelift station using these owner supplied items.

Work is to be completed within fifteen (15) weeks after contractaward. The estimated cost for this opportunity is within the following category: $251K to $500K.

CONSTRUCTION SCOPE: The construction scope includes but is not limited to the following: 1. Excavation, backfilling, and surface reinstatement ;and 2. Installation of a new wet well (pre-manufactured in FRP) forming the new sewage lift station; and 3. Re-direction of existing gravity sanitary sewers from the existing sewage lift station location to a new maintenance manhole which in turn will dischargeto the new wet well.

New wet well, maintenance manhole, pumps, and control panel will be provided by the Owner. A cast-in-place concrete hold down / anti-floatation pad must be installed below the FRP tank to suit site conditions. Construction of the new sewage lift station must be completed in advance of the phased cutover of existing building services from the existing wet well to the new wet well to ensure uninterrupted sanitary service to the facilities at 335 River Road. During the switch overfrom the existing pumping station to the new pumping station, the Contractor must provide temporary by-pass pumping to ensure no disruption to facility sanitary service.

The gravity service discharge piping to the existing sewage lift stationmust bereplaced and routed to the new wet well. The existing concrete wet well must be decommissioned and broken down below ground water level.The construction of thenew pumping system must be completed in phases with each service connection completed one at atime with the use of temporary pumping. Uninterrupted full sanitary sewage discharge must remain in-service during the ECC’s campus working hours, 7am to 6pm.

The new duplex pumps for the well must be installed with a breakaway connection along withseparate lift chains and guide rails. The pumping station chamber will also be equipped with a local electrical control panel providedbythe Owner. This control panel contains all of the starters required for the duplex pump configuration along with the float controls for the pumps. The existing electrical service must be reused to feed the new pumps. The new sewage lift station pumpsmust be electrically equivalent to the existing pumps.

MANDATORY INDUSTRIAL SECURITY REQUIREMENT

This procurement contains a mandatory security requirement. At bid closing, the Bidder must hold a valid Designated Organization Screening (DOS) at level of Reliability Status. Failure to comply with this requirement will render the Bid non-compliant and no further consideration will be given to the Bid.

OPTIONAL SITE VISIT

There will be an optional site visit on Tuesday, August 9th at 10:00AM. Although the site visit is optional, it is strongly recommended to attend to view the difficult site conditions and government owned equipment on site. Interested bidders are to meet at the front security desk at 335 River Road, Ottawa, Ontario (southof Hunt club road and the Airport).

All Contractors will be issued a day pass upon verification of a valid pieceof ID. There are no mandatory health and safety requirements for this site visit.

Parking: The front parking lot by the main entranceisvisitor parking and parking is free.

ENQUIRIES: All enquiries are to be submitted to the Contractual AuthorityAmanda Hoffman Tel: 873-469-4930 or by email at amanda.hoffman@pwgsc.gc.ca.

Enquiries are to be made in writing and should be received no less than five (5) calendar days prior to the closing date to allow sufficient time to respond.

BID DOCUMENTS

Firms intending to submit bids on this project should obtain bid documents through the Government Electronic Tendering Serviceat http://Buyandsell.gc.ca/tenders or at the toll-free number 1-855-886-3030. Amendments, when issued, will be available from the same government electronic tendering service.

Firms that elect to base their bids on bid documents obtained from other sources do so at their own risk and will be solely responsible to inform the bid calling authority of their intention tobid.

BID RECEIVING: Sealed bids will be received at: Public Works and Government Services Canada, Bid Receiving Unit, Place duPortage, Phase III, Main Lobby Core 0B2, 11 Laurier Street, Gatineau, Quebec, K1A 1C9. Delivery Date: Above-mentioned

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Construction
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 5 amendments. CanPursue observed 1 of them with dates.

  • Amendment 5Aug 25, 2016
  • Original noticeJul 28, 2016

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
EP076-162723/B
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account