CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Millimeter Wave Power Sensors | Industry Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Millimeter Wave Power Sensors

Industry Canada92031551Federal
Find on CanadaBuysAdd to pipeline
Published
Aug 23, 2021
Respond by
Sep 13, 2021
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

mmWave Thermal Power Sensors (Qty.x3)General Requirement PreambleThe Certification & Engineering Bureau (CEB) requires a quantity of 3, mmWave / Radio Frequency (RF) thermal power sensors in order to carry out regulatory compliance testing, standards development activities as well as measurement studies. Equipment Specification Requirements:The mmWave power sensor shall be interoperable with the CEB’s current mmWave 1 mm connector system. A 1 mm (male) connector shall be provided at the mmWave input port.The specification requirement is for hardware and software that will allow millimeter wave true average power (RMS) compliance tests and measurements on devices under test (DUT) or on power coupling devices.1)Mandatory Requirements1.1)General Hardware SpecificationsSpecification requirement:Frequency of operation for each power sensor: DC to >= 110 GHzThe RF test port connector shall be 1 mm male connectorInput power range is <= 300 nW to >= 100 mW (<= –35 dBm to >= +20 dBm)The mmWave thermal power sensor’s power supply must be fully integrated or powered via the USB portThe impedance of the RF test port connector shall be 50 ohmsSWR: DC to 18 GHz: <= 1.25; 18 GHz to 50 GHz: <= 1.50; 50 GHz to 110 GHz: <= 1.77Measurement uncertainty (Absolute): <= 0.35 (dB)Linearity shall be = <= 0.60 %Communications & control shall be made using one USB cable connectionAll cabling and connectors for general use shall be included1.2)Software RequirementsSpecification requirement:System must include software that allows data acquisition from a computer operating on MS Windows 10.System must include software that performs true average power (RMS) measurements from DC to >= 110 GHzSoftware must have a graphical interfaceSoftware must allow for automation of power measurements of any user duration selection between (0 and >18 minutes)Software must allow for automatic system verificationSoftware must contain a tabular measurement data report generatorThe software must allow connection of two or more power sensors within the same software interface for performing power measurements on multiple channels or device ports.The software must allow export of the measurement data for post processing via Microsoft (MS) Excel or other MS compatible applicationsThe software provided with the system shall not require a periodic software licensing fee1.3)Environmental RequirementsSpecification requirement:The manufacturer’s operating temperature range must be in the range of 0 degrees Celsius or lower to 50 degrees Celsius or higher. The maximum operating humidity must be equal to or higher than 70%.1.4)General Specifications1.4.1.Quality and ServiceSpecification requirement:The manufacturer of the system must have at least 10 years’ experience manufacturing electronic test equipmentThe system must not be manufactured using components that are older than 5 years.The system must include contact information for product support in the form of a website, email address and telephone number. Training on how to use the equipment shall be available upon requestThe system shall include contact information for product support in the form of a website, email address and telephone number. The support shall be available for at least 2 years after purchase.1.4.2.Calibration of EquipmentSpecification requirement:All measurement components of the system must be delivered with a certificate of calibration and data demonstrating compliance to all the manufacturers’ specifications as applicable. The calibration must be valid for at least 1 year after purchase.1.4.3.Delivery and BrokerageContract cost to include all delivery and brokerage charges, etc. FOB Innovation, Science and Economic Development Canada, Certification and Engineering Bureau, located at 3701 Carling Ave. bldg.# 94. Ottawa, Ontario, Canada K2H 8S2 (ph.# (613) 991-9311)

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

No related records observed.

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
92031551
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account