CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Elevator Repair & Inspection | Correctional Service of Canada (CSC) · CanPursue
Opportunities
Fit is part of the trial and paid plans.Cancelled

Elevator Repair & Inspection

Correctional Service of Canada (CSC)53000-25-5104094-AFederal
Find on CanadaBuysAdd to pipeline
Published
Aug 8, 2025
Respond by
Sep 8, 2025
Latest amendment
—2 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

The contractor must provide maintenance to the Elevating Devices. The contractor must provide a maintenance Log for each elevating device, in a manner that will identify the Contractor's adherence to the Maintenance Services, and the applicable Codes and Standards, as described in the Safety Codes. The Project Authority will use this Log as proof of service delivery should there be a discrepancy between services the contractor has rendered, and the services invoiced. The contractor must adhere to the maintenance requirements and intervals provided within the Elevating Devices Log as a minimum. Should the contractor deem that the maintenance requirements and intervals need to be increased for the elevating devices, the contractor must advise the Project Authority who must approve the increased services. The contractor must note the increased maintenance requirements and intervals in the Maintenance Logbook. The contractor must register all work performed on the equipment under this contract in maintenance logbook must include the equipment number, date, time of arrival, contracts employees s name, nature of the work performed, any identified problem(s) and actions taken to rectify them and time of departure. The Contractor must provide the Logbook at the start of the contract, which must be kept in the elevator machine room. The Project Authority will provide any site-specific examination and test frequencies for this contract which is provided in the tasks on statement of work. The contractor must provide an equipment specific Maintenance Control Program (MCP) as per the requirements of the regulatory Authority Having Jurisdiction and ASME A17.1/CSA B 44 Safety Code for Elevators (requirement 8.6.1.2.1). The contractor must adopt and comply with any portion of the MCP that is deemed more stringent than the Particular Requirements described in this statement of work. The contractor must maintain records of all maintenance activities, adjustments, verifications, tests, repairs and modifications for the duration of the contract, and provide them to the project authority upon request. When the contractor cannot return malfunctioning elevating equipment to service within the same day, the Contractor must provide, by the end of the following working day, a written report to the project authority describing the nature of the problem and the expected date of the service resumption. When the contractor determines it is necessary to take all or part of the elevator system(s) out of service for inspections, tests maintenance services and repairs, the contractor must make arrangements with the project authority a minimum of seventy-two (72) hours in advance). The contractor must provide details of the devices to be taken out of service electronically to the Project Authority outlining the scope of the work to be performed, anticipated time frame and the equipment involved. The Contractor must use proven information collection and delivery techniques, methodologies and systems as necessary to efficiently meet CSC requirements for regulatory reporting and documentation as well as invoice verification. The contractor must ensure that computer systems and information are protected with due regard to security and ensure disaster recovery and backup plans and procedures are in place to protect that information. The contractor must provide copies of all maintenance related work, tickets and visitation records with the invoices to allow the Project Authority to verify that the contractor meets inspection and maintenance frequencies stated in the contract.

Procurement

Category
Services
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 2 amendments. CanPursue observed 1 of them with dates.

  • Amendment 2Mar 2, 2026
  • Original noticeAug 8, 2025

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • Safety Vocational Training - H2S Alive and Confined SpaceNov 10
  • Victim-offender mediation (VOM) servicesNov 10
  • Sidewalk Replacement - JINov 12
  • PCB Transformer Replacements at Beaver Creek Institution -MinimumNov 12
  • Dental Chairs and Accessories for Multiple Sites in Ontario regionNov 13

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
53000-25-5104094-A
Observed
Sep 27, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account