Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.
Create free accountCreate a free account to see past contracts like this one: who won and at what price.
Create free accountTrade Agreement: NAFTA/AIT/Canada-Peru FTA/Canada-Colombia FTA Tendering Procedures: Generally only one firm has been invited to bid Attachment: None Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: Consolidated Stills and Sterilizers 76 Ashford Street Boston Massachusetts United States 02134-0003 Nature of Requirements: STERILIZERS
39903-130291/A Walkowiak, Peter Telephone No. - (819) 956-7534 Fax No. - (819) 956-3814
Canadian Food Inspection Agency (CFIA) has a requirement for the supply of quantity two (2) laboratory steam sterilizers for the purpose of sterilizing growth media, glassware and plasticware and for decontaminating biohazardous materials.
Delivery must be made on or before March 30, 2013.
It is proposed to negotiate on a limited tendering basis for interchangeability reasons, with Consolidated Sterilizer Systems, of Boston MA, who is the original equipment manufacturer. Consolidated Sterilizer Systems, is the only known supplier capable of satisfying the following mandatory technical specifications;
- Demensions must be 20" x 20" x 38" and 24" x 36" x 60" in order to fit existing enclosures. - Must have a Liquid cycle and Gravity cycle with Automatic and Manual mode capability. - Sterilizer chamber, jacket and doors must be constructed of stainless steel. - Must be equipped with 2 shelves evenly spaced. - Temparture must be adjustable in increments from 100 to 135 degrees centigrade. - Must be equipped with a touch control panel and display status, cycle phase, temparature (in degrees Celsius), pressure, time, warnings and minutes remaining in cycle. - Must be equipped with a printer in order to catalog cycles. - Must be able to run on in-house steam. - Must be programmable and automated with an Ethernet communication port capable of downloading information to a local laptop. - Must be equipped with an internal pressure door lock. - Must have a single manually operated radial arm door. - Electrical specifications must be 120 volts, 60hz, 1 phase wiring for the controls. - Displays, manuals and operation demonstartion must be in English. - Must have a 1/2" thermocouple port to allow the user to validate performance. - Must have the following safety features; system to prevent cycle start if the door seal is not established, prevent excessive condensation, prevent pressure build up, prevent door being opened until chamber has been sufficiently vented and comply with the following standards when applicable: Technical Standards and Safety Act, 2000, Ontario Regulation 220/01, Boilers and Pressure Vessels (Canadian registration number applied), as well as Canadian Standards Association Standard C22.2 No. 61010-1. - Must be equipped with an automatic wastewater cooling system to bring water temp below 140F. - Must have a surge suppressor for the controls.
Delivery Date: Above-mentioned
You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.
An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.
Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.
The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.
The Crown retains the right to negotiate with suppliers on any procurement.
Documents may be submitted in either official language of Canada.
Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user
No amendments observed.
No attachments listed in the open data.
No contact listed in the open data.