CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Swept Source Laser - Winnipeg, MB | Public Works and Government Services Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Swept Source Laser - Winnipeg, MB

Public Works and Government Services Canada31005-161780/AFederal
Find on CanadaBuysAdd to pipeline
Published
Dec 1, 2016
Respond by
Dec 16, 2016
Latest amendment
None

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Trade Agreement: NAFTA/AIT/Canada FTAs with Peru/Colombia/Panama Tendering Procedures: Generally only one firm has been invited to bid Non-Competitive Procurement Strategy: Exclusive Rights Comprehensive Land Claim Agreement: No Vendor Name and Address: THORLABS INC 56 Sparta Avenue NEWTON New Jersey United States 07860 Nature of Requirements:

Swept Source Laser - Winnipeg, MB

31005-161780/A Mack, Wayne Telephone No. - (306) 241-6435 ( ) Fax No. - (306) 975-5397 ( )

To supply a high speed swept source laser which will be part of a new optical coherence tomography (OCT) systemfor National Research Council (NRC), Winnipeg, MB. Delivery is mandatory by March 31, 2017.

Background: The swept source laser is one component of a larger optical coherence tomography (OCT) system. NRC have invested extensively in developing OCT control, acquisition and data processing software and hardware over the past 10 years. Accommodating a source with different operational characteristics could require a major redesign of the hardware and/or software requiring months of personnel time todevelop, build, test and validate.

Sole Source Justification: 1) Emission at a central wavelength located at 1310 nm +/- 15nm One of the applications for this OCT system is imaging biological tissue such as skin. Of the swept source laser wavelengths commonly available, 1310nm is the most suitable for these biological applications. Water (which tissue contains) has an absorption peak near 1550 nm reducing the depth of penetration of light into the sample therefore a 1550 nm laser would not beacceptable.

NRC intends to repurpose an existing interferometer for use with this laser. The laser’s wavelength scan range needs to fall within the operating wavelength range of the optical components in the interferometer. The optical components work in a wavelength range of 1310nm +/- 70nm so the laser’s wavelength sweep needs to fall within this range. Wavelengths outside the required range are not acceptable.

2) Minimum 200 kHz repetition rate with unidirectional wavelength scanning

OCT data is acquired by scanning a laser beam over an area building up an image one point at a time. The swept source laser’s repetition rate determines how quickly data from individual points are acquired - the faster the repetition rate the faster an image can be built up. NRC tissue imaging applications often involve living biological samples in which motion due to breathing, heartbeat, etc. is unavoidable therefore faster acquisition rates are necessary to eliminate or reduce motion artifacts. NRC’s industrial imaging applications where the sample is in motion (for instance a conveyor belt or assembly line) also require fast scanning rates in order to acquire images with required scan spacing (resolution) to meet the application requirements withoutreducing production (conveyor) speed. 200 kHz swept sources are currently commercially available, therefore to ensure that NRC continues to offer clients state of the art OCT capabilities we require a minimum 200 kHz swept source.

In applications where motion is a factor (see examples above), using a 100 kHz source instead of a 200 kHz source would effectively reduce our imaging resolution by a factor of 2. This reduction in resolution or production throughput would be an unacceptable drop in performance.

Unidirectional scanning is needed due to compatibility issues. Existing software would need to be modified to handle bi-directional scanning. Non-unidirectional scans exhibit interlace patterns in the scan images which degrade image qualityand increase the computation required for automation of image processing and machine learning.

3) Wavelength tuning range of at least 100 nm in width with continuous, mode-hop¬ free operation

The axial resolution of the OCT system is inversely proportional to the wavelength sweep range of the swept source laser. To get the axial resolution needed for imaging biological tissue and NRC’s industrial applications NRC needs a scan width of at least 100 nm. The axial resolution enables differentiation of layered features and 3-D structures within the sample (biological or industrial) and provides measurement accuracy of geometric thicknesses and dimensions in a cross-sectional image.

Continuous scanning is required for compatibilitywith our existing in-house written data acquisition software. Mode-hop free operation is required to avoid noise, provide smooth wavelength transition during sweeps and provide continuously smooth power during sweeps.

4) Minimum coherence lengthof 100 mm

Thecoherence length parameter of a swept source laser as it relates to OCT applications determines the maximum size of the depth ?window’ over which an OCT signal can be acquired. Longer coherence length sources make it possible to handle larger differences in height (depth) without adjusting the reference arm. Biological tissues are never flat and are often in motion. An increased depth window allows scanning larger areas without having to adjust the reference arm of the OCT system. Industrial applications often involve samples that are not flat or have components at different depths. Having an increased depth window in the OCT imaging system creates greater options for industrial imaging without having to adjust the reference arm. Swept sources with coherence lengths of 100 mm are currently commercially available. To ensure that NRC will continue in the future to offer clients state of the art OCT capabilities we require a swept source with at least 100 mm coherence length.

5) Average Output Power of at least 20mW

6) Commercially available at time of Advanced Contract Award closing. Prototypes are not acceptable.

Compatibility Factors

1) Existing OCT control, acquisition and data processing software and hardware

The software was developed in-house. The hardware includes the acquisition board, polarizer controllers, photo detectors and other optical and mechanical parts of the interferometer, reference arm and sample arm. Some of the optics, mechanicaland detector parts are from Thorlabs. The compatibility factors are the combination of the software and hardware to synchronize data acquisition, detect and digitize the optical signal, and process the acquired data to generate a structural image of thesample. The control software operation and hardware acquisition are dependent on the swept source having properties of wavelength scan range, continuous wavelength sweep operation, unidirectional, mode-hop free, wavelength sweeping to provide for systemoperation.

Newlaser must be compatible with the existing hardware and software

1. Existing software is designed for unidirectional wavelength sweeps. Adapting the software to compensate for other sweep configurations (bi-directional, etc.) would require significant software modifications.

2. Existing software is designed for continuous wavelength sweeps. Adapting the software to compensate for breaks or other inconsistencies (such as mode-hop) in the wavelength sweep would require significant software modifications.

3. NRC’s interferometer’s optical components accept wavelengths in the range of 1310nm +/- 70nm so the sweep range of the laser needs to fall within this range.

Total Estimated Cost: $48,485.81CDN

Thorlabs is the only company that can supply a swept source laser with the above specifications which are operationally justified.

GCR Exemption: d) only one supplier (person or firm) is capable of performing the contract.

NAFTA Limited Tendering Reason: (b)where, for works of art, or for reasons connected with the protection of patents, copyrights or other exclusive rights, or proprietary information or where there is an absence of competition for technical reasons, the goods or services can be supplied only by a particular supplier and no reasonable alternative or substitute exists;

(d) for additional deliveries by the original supplier that are intended either as replacement parts or continuing services for existing supplies, services or installations, or as the extension of existing supplies, services or installations, where a change of supplier would compel the entity to procure equipment or services not meeting requirements of interchangeability with already existing equipment or services, including software to the extent that the initial procurement of the software was covered by this Chapter.

AIT Article 506: 12) to ensure compatibility with existing products, to recognize exclusive rights, such as exclusive licences, copyright and patent rights, or to maintain specialized products that must be maintained

Delivery Date: Above-mentioned

You are hereby notified that the government intends to negotiate with one firm only as identified above. Should you have any questions concerning this requirement, contact the contracting officer identified above.

An Advance Contract Award Notice (ACAN) allows departments and agencies to post a notice, for no less than fifteen (15) calendar days, indicating to the supplier community that it intends to award a good, service or construction contract to a pre-identified contractor. If no other supplier submits, on or before the closing date, a Statement of Capabilities that meets the requirements set out in the ACAN, the contracting authority may then proceed with the award. However, should a Statement of Capabilities be found to meet the requirements set out in the ACAN, then the contracting authority will proceed to a full tendering process.

Suppliers who consider themselves fully qualified and available to provide the services/goods described herein, may submit a statement of capabilities in writing to the contact person identified in this Notice on or before the closing date of this Notice. The statement of capabilities must clearly demonstrate how the supplier meets the advertised requirements.

The PWGSC file number, the contracting officer's name and the closing date of the ACAN must appear on the outside of the envelope in block letters or, in the case of a facsimile transmission, on the covering page.

The Crown retains the right to negotiate with suppliers on any procurement.

Documents may be submitted in either official language of Canada.

Procurement

Category
Goods
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

No amendments observed.

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • High Density Mobile ShelvingDec 15
  • Accommodations - Temecula, CaliforniaMar 31
  • Accommodations - Borrego Springs, CaliforniaMar 31
  • Medium/Large Vessel Recycling ServicesMar 30
  • Furniture for Work SpacesApr 23

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
31005-161780/A
Observed
Sep 18, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account