CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Fire Panel Upgrade | Correctional Service Canada · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Fire Panel Upgrade

Correctional Service Canada21440-24-4513158Federal
Find on CanadaBuysAdd to pipeline
Published
Nov 23, 2023
Respond by
Dec 21, 2023
Latest amendment
—6 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

Nature of Requirements

The following is a summary of the statement of work for this requirement.

The Correctional Service Canada has a requirement to replace existing Siemens MXL Fire Alarms panels in ten (10) locations at Collins Bay Institution in Kingston, Ontario. This project is to upgrade the panels through the migration of Siemens MXL to the Desigo Modular system to maintain compliance monitoring and detection with the institution’s fire alarm and detection systems.

The new Desigo Modular fire panel system is “Backward Compatible” which means it can successfully use interfaces and data from, and work seamlessly with, the existing detection components, allowing the straightforward replacement of the MXL System. All existing detection components already installed in the selected buildings in Collins Bay, will operate directly with the new panels. As well, three (3) display panels require upgrading at the Minimum unit and a PAD Bell Booster panel in CBA10 at Collins Bay Institution.

Objectives: Provide the most up to date fire safety for staff and inmates of Collins Bay Institution.

Deliverables: The contractor must perform the following tasks: Supply all labour and materials to complete the work. Supply and install Desigo Modular system upgrades to replace the MXL systems in following locations: Medium Unit: 1. Medical Centre/ Keepers Hall CBA14/CBA13 (Node # 2) 2. CBB1-UM Unit Management (Node # 5) 3. Administration* CBA1/CBA10** (Node # 7) 4. CBI bldg. 6 (CBB6) (Node # 12) 5. CBI bldg. 7 (CBB7) (Node # 13) 6. CBI bldg. 8 (CBB8) (Node # 14) 7. Kitchen and Strip CBC2 CBB2 (Node # 16) 8. CBI Programs (CBC36) (Node # 17) Minimum Unit: 9. Phoenix Building FF36 (Node # 1) 10. CBI Bldg.11 - FF11 (Stores/Chapel/Works) (Non-Networked) Desigo Modular Panels – Displays only - To Be Upgraded in the following locations: a. FF32N Basement b. FF32N Horseshoe/First floor c. FF46 South Unit

* Fishbowl backbox to remain, supply new PAD Bell Booster panel to replace CP-35 (building CBA10). **This location/node has 30-Year-Old XL3 detectors which are not backward compatible with XLS. The contractor must upgrade the following devices in this location with compatible devices: a. 6 DI-X3 Addressable Smoke Detectors b. 9 DI-BX3 Addressable Duct Smoke Detectors c. 2 TRX-1 Addressable Interface Modules

• Complete the programming on all above fire panel systems being installed. • Configure new displays to existing panels and program them to operate as intended. • Verify all new equipment as per CAN/ULC. • Re-program the existing custom configuration software, to maintain existing Sequence of Operation programming and ULC listing. • Hand over any Materials in operational condition and compatible with other detection systems at the institution to the CSC representative for spares or other uses. • Perform any required miscellaneous electrical work (i.e., 120 VAC isolation) during panel upgrades.

All fiber optic drivers/REP repeater boards must remain. All existing conduit, wiring, signaling devices, sprinkler switches, must remain.

The contractor must make arrangements for all required testing and is responsible for obtaining all licenses and permits associated with this project. During the Warranty period, the contractor must maintain the newly installed equipment, and have access to Siemens support services, including, but not limited to: a. Marketing Updates. b. Firmware or software releases. c. TechALERT notices. d. Product Application notices.

Procurement

Category
Construction
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 6 amendments. CanPursue observed 1 of them with dates.

  • Amendment 6Dec 21, 2023
  • Original noticeNov 23, 2023

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

No related records observed.

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
21440-24-4513158
Observed
Sep 27, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.