CanPursue

Research

  • Search
  • Opportunities
  • Buyers
  • Suppliers
  • Contracts
  • Awards

Intelligence

  • OverviewAccount required
  • WatchlistsAccount required
  • PipelineAccount required
  • IntelligenceAccount required
Create free account

Sign in

⌘K
ENFR
Inspection of Water Based Fire Safety Systems | Correctional Service of Canada (CSC) · CanPursue
Opportunities
Fit is part of the trial and paid plans.Closed

Inspection of Water Based Fire Safety Systems

Correctional Service of Canada (CSC)21422-30-5060308Federal
Find on CanadaBuysAdd to pipeline
Published
May 23, 2025
Respond by
Jun 13, 2025
Latest amendment
—3 amendments

See how this opportunity fits your company

Create a free account and describe your company. With the trial, CanPursue checks every opportunity against it and explains the fit.

Create free account

Who won similar work

Create a free account to see past contracts like this one: who won and at what price.

Create free account

Description

The Correctional Service Canada (CSC) is required by law to ensure that fire protection services in CSC institutions are up to date with accurate reporting measures taken. CSC requires the services of an experienced third-party Contractor to ensure it is compliant with health and safety requirements at Beaver Creek Institution.

Objectives: The Contractor must perform sprinkler inspections, fire hydrant flow tests, fire hose and cabinet inspections, and test sprinkler backflow preventers, pre-action systems and fire department connections as required under federal, provincial, and municipal legislation. The Contractor must perform the inspections, testing, maintenance and certifications annually, semi –annually and quarterly throughout the calendar year as per NFPA 25 standards.

Deliverables: • The Contractor must perform inspections, testing and maintenance on the following Water Based Fire Safety Systems at Beaver Creek Institution – Minimum and Medium as per NFPA 25 standards: a) Sprinklers b) Sprinkler Back Flow Preventers c) Pre-Action Systems d) Fire Hydrants e) Fire Hose and Cabinets f) Fire Department Connections • The Contractor must provide individual deficiency reports for each inspection and testing (quarterly, semi-annual, annual) on the Water Based Fire Safety Systems at Beaver Creek Institution – Minimum and Medium as per NFPA 25 standards (Please see 3.7.1 Deficiency Reports below): a) Sprinklers b) Sprinkler Back Flow Preventers c) Pre-Action Systems d) Fire Hydrants e) Fire Hose and Cabinets f) Fire Department Connections • The Contractor must provide individual final reports for each inspection and testing (quarterly, semi-annual, annual) on the Water Based Fire Safety Systems at Beaver Creek Institution – Minimum and Medium as per NFPA 25 standards (Please see 3.7.2 Final Reports below): a) Sprinklers b) Sprinkler Back Flow Preventers c) Pre-Action Systems d) Fire Hydrants e) Fire Hose and Cabinets f) Fire Department Connections • The Contractor must supply all tools, labour, materials and mechanical devices necessary to complete all applicable inspections, testing and maintenance required to obtain certification of the Water based Fire Safety Systems at Beaver Creek Institution – Minimum and Medium. • The Contractor must have all quarterly, semi annual and annual inspections industry regulated testing and applicable certifications (NFPA 25) completed at the expense of the Contractor. • The Contractor must identify and notify the Project Authority of any repairs required to complete the Fire Alarm System inspection and certification. The Project Authority will then arrange for any required repairs including parts and labour with the proprietary rights holder of the Fire Panel, if required. • If required, any inspection and testing that requires the OEM proprietary rights holder of the Fire Safety System (Edwards/Chubb) to participate, the Contractor is responsible for any work and associated costs for having the OEM proprietary rights holder assist in the applicable inspection and testing. o Note: The main panel is located in the MCCP area at the Medium and in the Duty Office at the Minimum. There are various panels in the institution that connect to the main panel. • The Contractor must exercise extreme care when testing units inter-connected to computer rooms and must perform this testing at the advisement and in close coordination with the Project Authority and CSC Informatics personnel. • The Contractor must ensure that all inspected systems are left in working order at the end of the contractor’s workday. If the Contractor cannot leave a system in working order, the Contractor must notify the Chief of Facilities Management before the Contractor leaves the site, and the Contactor must ensure that there are alternative arrangements in place for any affected systems. • The Contractor must silence the alarm bells system during testing and return the system to operation after the inspection is complete.

Procurement

Category
Services
Jurisdiction
Federal

Not stated in the notice: procurement type, procurement method, selection criteria, region of delivery, region of opportunity, expected contract period, end user

Requirements and qualifications

Supply arrangement
Not stated in the public notice
Security requirement
Not stated in the public notice
Trade agreements
—
Limited tendering reason
—

Classification

GSIN
—
UNSPSC
—

Amendments

The source reports 3 amendments. CanPursue observed 1 of them with dates.

  • Amendment 3Jun 13, 2025
  • Original noticeMay 23, 2025

Documents

No attachments listed in the open data.

Contact

No contact listed in the open data.

Related

More from this buyer

  • Replacement of the Perimeter Intrusion Detection System (PIDS) Integration Unit (PIU) and the Facility Alarm Annunciation System (FAAS) Integration Unit (FIU) at Mission InstitutionNov 9
  • Sidewalk Replacement - JINov 10
  • Safety Vocational Training - H2S Alive and Confined SpaceNov 10
  • Victim-offender mediation (VOM) servicesNov 10
  • PCB Transformer Replacements at Beaver Creek Institution -MinimumNov 12

Linked contracts

No related records observed.

Source

Find on CanadaBuys

CanPursue has no direct link to this notice. This opens a CanadaBuys search for its solicitation number.

Source
CanadaBuys
Solicitation
21422-30-5060308
Observed
Sep 27, 2026

The amount, value range and contract duration shown on some CanadaBuys pages are not in the open data, so CanPursue does not show them.

Never miss an amendment

Track this opportunity in your pipeline and watchlists with a free account.

Create free account